Event
ELECTRIC SCREW GUN, ELECTRICAL, E C, EQUIPMENT GROUNDING, ELECTRIC SHOCK
NAICS
000000
Inspection type
Accident-driven
Activity number
#14848675
Employer profile
COLUMBIA KITCHENS OF MD INC
Summary number
14195549
Report ID
352440

Event description

ELECTRIC SHOCK - FAULTY EQUIPMENT

Investigation abstract

AN EMPLOYEE WAS FABRICATING AND ASSEMBLING COUNTER TOPS AND SPLASHBOARDS FOR KIT CHENS. HE WAS WORKING ALONE ON A 4-FOOT-BY-12-FOOT TABLE IN A CORNER OF THE SHOP , USING A BLACK & DECKER, METAL-CASED SCREW GUN. THE ATTACHMENT PLUG ON THE ELEC TRIC TOOL'S SUPPLY CORD HAD ITS GROUNDING PRONG MISSING AND HAD NO COVER OVER TH E PLUG FACE. WHILE USING THE SCREW GUN, THE EMPLOYEE RECEIVED AN ELECTRIC SHOCK, FOR WHICH HE WAS TAKEN TO THE HOSPITAL. HOWEVER, THERE WERE NO BURNS OR OTHER P HYSICAL MANIFESTATIONS OF THE INJURY. THE WORKERS HAD BEEN TRAINED BY MANAGEMENT , AND EACH HAD BEEN INSTRUCTED TO REPORT ANY DEFECTS IMMEDIATELY.

Victim

  1. #1 Hospitalized Age 27 M

    Nature of injury
    10
    Part of body
    4
    Event type
    13
    Source
    21
    Occupation code
    657
    Human factor
    12
    Environmental factor
    18
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.