AVM OF SC, INC.

Event
AMPUTATED, POWER PRESS, FINGER, GUARD, INTERLOCK, THUMB, POINT OF OPERATION, PRESS
NAICS
000000
Inspection type
Accident-driven
Activity number
#15342801
Employer profile
AVM OF SC, INC.
Summary number
14215669
Report ID
454510

Event description

FINGER AND THUMB AMPUTATED IN POWER PRESS

Investigation abstract

EMPLOYEE #1 WAS ASSIGNED TO OPERATE A FULL REVOLUTION NIAGARA 35 TON POWER PRESS . THE PRESS WAS FITTED WITH AN "A" TYPE GATE. THE PRESS WAS SET UP TO ATTACH COV ERS ON CUPS FOR VACUUM ACTUATORS. THE EMPLOYEE WAS REQUIRED TO REACH INTO THE PO INT-OF-OPERATION TO PERFORM THIS JOB. THE TYPE "A" GATE MALFUNCTIONED. EMPLOYEE #1'S THUMB AND FIRST FINGER ON HER RIGHT HAND WERE AMPUTATED. THE PRESS WAS LOCA TED ON THE MOTOR LINE IN THE PRODUCTION AREA.

Victim

  1. #1 Hospitalized Age 29 F

    Nature of injury
    1
    Part of body
    10
    Event type
    1
    Source
    26
    Occupation code
    706
    Human factor
    9
    Environmental factor
    1
    Task assigned
    2