105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14415194

OSAGE OUTDOOR ADVERTISING INC

Event
REPAIR,E GI IV,ELECTRICAL,ELECTROCUTED,LOCKOUT,ELEC CIRC PART--MISC,ADVERTISING SIGN
NAICS
000000
Inspection type
Accident-driven
Activity number
#1557784
Employer profile
OSAGE OUTDOOR ADVERTISING INC
Summary number
14415194
Report ID
728500

Event description

ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

Investigation abstract

Three employees were rebuilding the wooden portions of a large billboard. They w nd. The injured employee died of electrocution. ere working from 6.1-meter-high (20-foot-high) scaffolds and on 10.7-meter-high (35-foot-high) stringers. There were no guardrails or safety lines protecting th e workers. The employees had not opened the disconnect for the electrical system but were relying instead on a timer and an electric eye. The circuit became ene rgized intermittently either due to a fault or vibration. One employee apparentl y contacted energized parts and received an electric shock. One of his coworkers tried to lower the injured employee to the ground with a rope. Unfortunately, t he coworker could not hold the weight, and the injured employee fell to the grou

Victim

  1. #1 Fatality Age 26 M

    Nature of injury
    10
    Part of body
    4
    Event type
    13
    Source
    15
    Occupation code
    999
    Human factor
    1
    Environmental factor
    18
    Hazardous substance
    8870
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.