Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31

OSHA Accident Investigation · Summary #14458962

M S WILLETT CO INC

Event
PULL BACK DEVICE, AMPUTATED, POWER PRESS, FINGER, POINT OF OPERATION
NAICS
000000
Inspection type
Accident-driven
Activity number
#14865430
Employer profile
M S WILLETT CO INC
Summary number
14458962
Report ID
352420

Event description

THUMB AMPUTATED IN MECHANICAL POWER PRESS

Investigation abstract

EMPLOYEE WAS OPERATING A MINSTER POWER PRESS. WHILE DOING SO HE WAS REACHING INT PLOYEE WAS INSTRUCTED IN THE USE OF PULL BACK DEVICES PRIOR TO THE ACCIDENT. AT THE TIME OF THE ACCIDENT THE EMPLOYEE WAS WEARING GLOVES, SO THE CONDITION COULD NOT BE OBSERVED BY THE SUPERVISOR, BECAUSE THE EMPLOYEE WAS WEARING THE WRISTLE T INSIDE THE GLOVE. O THE DIE AREA PLACING AND REMOVING PARTS. THE EMPLOYEE WAS WEARING PULL BACK DE VICES AT THE TIME THE ACCIDENT OCCURED. THE EMPLOYEE REMOVED THE PULL BACK WRIST LETS TO GO TO THE RESTROOM. WHEN HE RETURNED TO THE MACHINE HE SLIPPED THE WRIST LETS BACK ON, BUT DID NOT TIGHTEN THEM AROUND HIS WRIST. THE LOOSE STRAP BECAME ENTANGLED ON A BOLT WHICH SECURED THE STRIPPED PLATE OF THE DIE. WHEN THE LOOSE STRAP BECAME ENTANGLED, THE OPERATING MECHANISM OF THE PULL BACK DEVICE BROKE, R ENDERING THEM INOPERATIVE. AT THIS POINT THE EMPLOYEE'S RIGHT HAND WAS CAUGHT IN THE DIE AREA, WHICH CAUSED THE AMPUTATION OF THE EMPLOYEE'S RIGHT THUMB. THE EM

Victim

  1. #1 Hospitalized Age 24 M

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    14
    Environmental factor
    3
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.