105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14459457

PRIMO ELECTRIC COMPANY

Event
DIGGER-DERRICK,HEAD,RIGGING,ELEC UTILITY WORK,MECH MAT HANDLING,NECK,STRUCK BY,LOAD LINE,UTILITY POLE
NAICS
000000
Inspection type
Accident-driven
Activity number
#14841704
Employer profile
PRIMO ELECTRIC COMPANY
Summary number
14459457
Report ID
352420

Event description

Employee Injured by Swinging Utility Pole

Investigation abstract

An electrical contractor was removing a utility pole. The 1-meter-diameter wood had been attached below the pole's center of gravity. pole was removed from the ground by a polecat hydraulic digger-derrick. The load line was attached to the pole about 1 meter from the ground, and the pole claw was about 2.1 meters from the top. The pole was pulled out of the ground and tra nsported 60 meters. Two employees were near the bottom of the pole when the pole was to be lowered to the ground. The pole came loose from the claw and pivoted on the load line. The bottom end of the pole struck an employee and hurled him i nto the boom. The employee received head and neck injuries for which he was hosp italized. The pole had been improperly pulled from the ground, and the load line

Victim

  1. #1 Hospitalized Age 53 M

    Nature of injury
    12
    Part of body
    13
    Event type
    6
    Source
    24
    Occupation code
    575
    Human factor
    11
    Environmental factor
    6
    Task assigned
    2

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.