105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14482004

SANITARY BOTTLING CO INC

Event
STORAGE TANK,EXPLOSION,CARBON DIOXIDE,TANK
NAICS
000000
Inspection type
Referral
Activity number
#1759901
Employer profile
SANITARY BOTTLING CO INC
Summary number
14482004
Report ID
316400

Event description

EXPLOSION OF CO2 STORAGE TANK

Investigation abstract

A SOFT DRINK MANUFACTURER HAD A 3 TON CAPACITY CARBON DIOXIDE (CO2) RECEIVER TAN K AT THE PLANT. THE TANK CONTAINED 2000 POUNDS ON THE DAY OF THE EXPLOSION. THE ESTABLISHMENT WAS EVACUATED DUE TO FLOODING RIVER WATERS IN THE AREA. THE PLANT WAS SECURED AND EVACUATED. NO EMPLOYEES WERE AT THE WORKPLACE. SUDDENLY, THE STO RAGE TANK ROCKETED 100 FEET INTO A NEARBY HOUSE. POSSIBLE CAUSES: 1. THE FLOOD W ATERS ROSE TO A LEVEL ABOVE THE 2 SAFETY RELIEF VALVES, CAUSING THE VALVES TO FR EEZE UP. THE TANK WAS THEN UNABLE TO VENT. THE PRESSURE BUILT UP AND THE TANK BL EW. 2. THE PIPING SYSTEM MIGHT HAVE BEEN DISCONNECTED FROM THE TANK DUE TO WATER PRESSURE. THE SAME EFFECT COULD OCCUR.

Victim

  1. #981 Degree 0 Age 0

    Nature of injury
    0
    Part of body
    0
    Event type
    0
    Source
    0
    Occupation code
    0
    Human factor
    0
    Environmental factor
    0
    Task assigned
    0

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.