Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31

OSHA Accident Investigation · Summary #14550412

FLEX PRODUCTS INC

Event
GRINDER, AMPUTATED, CLEANING, EQUIPMENT FAILURE, ARM
NAICS
000000
Inspection type
Accident-driven
Activity number
#3223526
Employer profile
FLEX PRODUCTS INC
Summary number
14550412
Report ID
454712

Event description

ARM AMPUTATED IN PLASTIC GRINDER

Investigation abstract

EMPLOYEE #1 WAS ATTEMPTING TO CLEAN PLASTIC OUT OF A GLOUCESTER GRINDER, MODEL # 1012 BP-10, WHEN HE REACHED INTO THE MACHINE TO REMOVE A DEFLECTING SCREEN TO F ACILITATE THE CLEANING PROCESS, THE MACHINE ACTIVATED. HIS LEFT ARM WAS PULLED I NTO THE GRINDING MECHANISM AND AMPUTATED JUST ABOVE THE ELBOW. A FAULTY ELECTRON IC SAFETY SWITCH WAS RESPONSIBLE FOR THE ACCIDENTAL ACTIVATION OF THE MACHINE.

Victim

  1. #1 Hospitalized Age 21 M

    Nature of injury
    1
    Part of body
    17
    Event type
    2
    Source
    43
    Occupation code
    709
    Human factor
    9
    Environmental factor
    3
    Task assigned
    1