Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31

OSHA Accident Investigation · Summary #708560

MORTON THIOKOL INC/WASATCH DIVISION

Event
STATIC ELECTRICITY, FIRE, EXPLOSION
NAICS
000000
Inspection type
Accident-driven
Activity number
#3264637
Employer profile
MORTON THIOKOL INC/WASATCH DIVISION
Summary number
708560
Report ID
854910

Event description

FIRE AND EXPLOSION IN ROCKET MOTOR PLANT

Investigation abstract

ON AUGUST 2, 1985, AT APPROXIMATELY 11:14 PM, AN EXPLOSION OCCURRED AT BUILDING M-75 AT THE MORTON THIOKOL PLANT IN BOX ELDER COUNTY, UTAH. THE EXACT CAUSE OF T HE EXPLOSION IS NOT KNOWN, HOWEVER IT IS BELIEVED TO HAVE STARTED IN THE FINAL P RODUCT BAG HOUSE, SPREAD TO THE LARGE DRYER AND THEN TO THE DUST COLLECTION SYST EM. THE DRYER, FINAL PRODUCT COLLECTION SYSTEM AND DUST COLLECTOR BURNED AT A HI GH SPEED, GENERATING HIGH PRESSURES AND BURSTING THESE ENCLOSED SYSTEMS. THE RES ULTING FIRE DESTROYED THE INGREDIENT PREPARATION AREA AS WELL. THE PROBABLE CAUS E OF THE INCIDENT IS A STATIC DISCHARGE FROM THE MATERIALS MOVING THROUGH THE SY STEM. THERE WERE NO INJURIES.

Victim

  1. #981 Degree 0 Age 0

    Nature of injury
    0
    Part of body
    0
    Event type
    0
    Source
    0
    Occupation code
    0
    Human factor
    0
    Environmental factor
    0
    Task assigned
    0

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.