Other fall to lower level 26 to 30 feet · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at KAP Contracting Co., Inc., Smyna Leipsic Road, SMYRNA, DELAWARE 19977
on — Fractures, affecting the lumbar region.
Final narrative
At approximately 8:10 p.m., on 3/25/15, an employee fell 20 to 30 feet from an articulating boom bucket to the ground. The employee was tightening bolts for mast arms on traffic signal lights when the clip tie-off point broke and the employee fell. The employee sustained cracked lumbar vertebrae and head lacerations.
HospitalizedLumbar regionBoom truck, bucket or basket hoist truck
An employee was laying down bridging (angle iron that is welded onto open web joists). He was moving backward toward the edge of a joist when his foot slipped. He lost balance and fell backward away from the structure and landed on the ground about 30 feet below. The employee sustained a broken right leg. The employee was wearing a harness but it was not connected at the time of the fall.
On June 16, 2023, an employee was checking the I-beams on a bridge. He unhooked his harness to move across the section of the second beam. While hooking his harness on the third beam, his foot hit the cable that was connected to the beam and fell approximately 25 to 30 feet to the muddy clay floor below. The employee sustained a left hip and femur fracture.
An employee was using a 60-foot ladder to access the fourth floor of a building in order to paint the balcony. The employee was holding onto the handrail while painting it when the handrail brackets broke, causing him to fall approximately 30 feet to the ground and land on top of air conditioning units. The employee suffered severe lacerations on the face and fractures to the cheekbones and eye bones. The employee was hospitalized.
An employee entered a portable structure that was being rigged up to a crane. The crane began lifting the portable structure with the employee inside when the structure fell 15-30 feet to the ground. The employee sustained a left leg fracture, a dislocated right ankle, and back injury.
More severe injuries in this industry (NAICS 238210)
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.
A flagger was directing traffic flow in a highway work zone. They were standing approximately 1.5 feet behind the shoulder's demarcating line, next to and slightly behind a traffic drum. As they were directing traffic into and out of the driveway of a parking lot, a car attempted to get around a truck and struck the traffic drum, which subsequently struck the employee, who was thrown 15 feet and landed on top of concrete aggregate. The employee suffered pelvic and rib fractures, T10 and L3 vertebra fractures, and internal bleeding.
An employee was troubleshooting a power washer in the field. Because there might have been water in its fuel, he brought it back to the shop and drained about a gallon of fuel from the tank into a plastic container. Some of the fuel spilled onto the floor and ignited. The employee was stomping out the fire when he lost his balance and tripped into a stool, which caused the plastic container to spill more fuel onto the fire. The employee's pants and shirt caught on fire, and he fell, abrading his knee while trying to get through the flames. As well as the knee abrasion, he suffered burns to the left leg and left lower quadrant of the torso. He was hospitalized.
An employee was backing up a tram (towing powered industrial equipment) to connect it to a trash bin. The employee's left forearm/wrist was caught and crushed between the tram and the bin. The employee was hospitalized.
An employee went to lift a carton and tripped on a different carton that was on the floor. She fell on the floor in the backroom and sustained a fractured right hip, and abrasions to her arm and knee. The employee was hospitalized and required surgery.