Elektro Fischer USA, LLP

Struck by dislodged flying object, particle · Fractures

Federal OSHA recorded a severe workplace injury at Elektro Fischer USA, LLP, 4915 Hwy 125, URANIA, LOUISIANA 71480 on — Fractures, affecting the foot (feet), unspecified.

An employee was covering a manhole with a manhole cover. The manhole cover flipped up on top of the employee's right foot, breaking four bones.

Hospitalized Foot (feet), unspecified Manhole and cistern covers

Lowe's Home Improvement

An employee was tossing a damaged toilet into a compactor. The toilet bounced off the compactor and lacerated the employee's right wrist, cutting an artery and tendon.

S & J Construction, LLC

An employee was operating a hydraulic jack to bend a frame when the jack came loose and struck the employee. They were hospitalized for a spleen injury.

RMVK Enterprise, INC.

A truck had been towed into the shop with a flat tire and a blown airbag. An employee checked the tire for damage and was airing the tire. The employee was installing the valve core when the bead slipped off the rim. Air escaped, and the aluminum wheel struck the employee's head and face. The employee became unresponsive and was bleeding.

Dustrol Inc.

On December 14, 2023, at 8:40 p.m., three employees were inspecting milling machines for startup. A few of the sleeves on the mill drum needed to be changed out. The injured employee was trying to input a sleeve on the mill drum using a hammer. The hammer hit the edge of the drum, which caused a metal piece to splinter off and strike the employee's cheek just below the left eye. The metal splinter embedded in the back of their eye socket, resulting in pain, swelling, and bleeding that required hospitalization.

WalMart #436

An employee was pushing a line of carts into a vestibule when the door cable snapped and struck his right ankle. The employee suffered a fracture that required surgery and hospitalization.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

Mintcrest Corp

An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.

Cupertino Electric, Inc.

An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.

Swedberg Electric, LLC

The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.

Kisatchie Midnight Express

A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.

CHRISTUS St. Frances Cabrini Hospital

A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.

Jean Simpson Personnel Services, Inc.

A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.

Calvary Industries Inc

An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.