Struck against stationary object or equipment, n.e.c. · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Chemtrade Solutions, 500 N 9th St., MIDLOTHIAN, TEXAS 76065
on — Amputations, affecting the fingertip(s).
Watch Chemtrade Solutions — freeGet an email when a new federal OSHA severe-injury report for Chemtrade Solutions is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was re-assembling a cooler rotary valve after shut down. Before installing the cover, he felt inside the piping to check for moisture when the blade made contact with his left-hand middle finger, partially amputating the fingertip under the nail.
AmputationFingertip(s)Cooling and humidifying machinery and appliances, n.e.c.
An employee was unnesting tote bags when her grip slipped and the back of her left hand hit a box containing a steel step stool that was adjacent to the tote bags. The employee's hand was fractured.
An employee was cleaning up and putting away equipment when the second toe on her right foot was stubbed on a fixture, resulting in hospitalization and a subsequent amputation of the toe.
An employee was walking when he tripped on a concrete vault lid, jamming his big toe into the tip of his steel toe boots. The employee's big toe was medically amputated.
An employee was cleaning a bathroom. As the employee bent over, the corner of a sink hit the employee's right eyeball, causing an injury that required hospitalization and surgery.
On September 23, 2023, an employee was cleaning near a conveyor when they knelt with their right knee on the floor. Their knee contacted a small piece of glass on the floor, resulting in a laceration that required hospitalization.
More severe injuries in this industry (NAICS 325998)
An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.
An employee was removing a hose from a chemical tank after filling the tank with hexamethylenediamine (HMD). He checked the line to ensure that the hose was clear, then disconnected the hose at the connection. Residual chemical sprayed onto his face, causing a second-degree burn. He was hospitalized.
Two employees were moving a railcar (plastic pellet hopper car) using a mobile railcar mover. One employee was the engineer in control of the railcar mover and the injured employee was a switchman. The railcar mover went forward and the hopper railcar struck the injured employee, resulting in a severe crushing injury to the employee's right arm.
An employee was opening a filter housing in the potassium chloride production area and got sprayed with a hot solution of potassium chloride brine. The employee sustained thermal burns to their right hand and legs.
An employee was performing maintenance on a guillotine cutter machine. As the employee was placing a pin in the machine, his left middle fingertip was caught, resulting in a partial amputation to the finger. The machine was not locked out at the time.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.