PILLAR CONSTRUCTION INC.

Fall from collapsing structure or equipment, unspecified · Fractures

Federal OSHA recorded a severe workplace injury at PILLAR CONSTRUCTION INC., 1001 4th Street, SW, WASHINGTON, DISTRICT OF COLUMBIA 20024 on — Fractures, affecting the leg(s), unspecified.

Watch Pillar Construction INC. — free Get an email when a new federal OSHA severe-injury report for Pillar Construction INC. is published. One employer, no account, unsubscribe in one click.

An employee fell from a scaffold after a cable line broke, breaking his leg and requiring hospitalization.

Hospitalized Leg(s), unspecified Scaffolds-suspended staging

PILLAR CONSTRUCTION INC.

An employee was walking down built-in scaffolding steps. He slipped on the fourth step and landed on his back against the steps while sliding down. He suffered a lower back injury.

View PILLAR CONSTRUCTION INC.'s full OSHA safety record →

VON ALST OPERATING, LLC

An employee was on a step ladder applying glue to a panel when the ladder fell apart, causing the employee to fall to the floor. The employee sustained rib fractures.

AVI Foodsystems, Inc.

On December 5, 2023, an employee was loading product onto a freight elevator when the elevator fell with the employee inside. The employee sustained a right leg injury.

Sysco Central Alabama

On 11/28/2023, an employee was loading a cart with supplies to be delivered to a restaurant. He stepped onto a ramp to get into the back of a truck but the ramp fell to the ground, causing the employee to fall as well. The employee was hospitalized with a fractured ankle.

S R Products

An employee was climbing a 16-foot fiberglass extension ladder to access a roof so they could take measurements for a roofing quote. The employee had partially ascended the ladder when the ladder broke in half. The employee's foot was caught in a ladder rung resulting in an ankle fracture that required surgery.

CHI Health Good Samaritan Hospital

An employee was replacing a heating, ventilation, and air conditioning (HVAC) valve in a ceiling while standing on a ladder. The ladder collapsed while the employee was descending, causing them to fall to the floor. The employee sustained a broken wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Builders Installed Products of New York, LLC

An employee was closing a rear trailer door in the parking lot when they were struck by a forklift. The employee's lower left leg was crushed between the pallet on the forklift and the trailer. The employee sustained muscle damage to their lower leg.

FC Drywall

An employee was cutting wood with a circular saw. The machine lagged and cut the employee's finger. The employee required surgical amputation of the finger at the hospital.

Garland Insulation

An employee was climbing a 12-foot ladder when he lost his balance and fell from the eighth rung to the ground. He sustained multiple broken ribs, which caused lung punctures.

Rochester Davis Fetch Corporation

An employee was installing spray-on fire proofing from a scissor lift. The scissor lift tipped over and the employee fell, resulting in multiple fractures to their leg, shoulder, and skull.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Goodrich Fire & Life Safety

An employee was assembling a baker type scaffold. He was beginning to transverse down the scaffold, approximately six feet off the ground, when the scaffold tipped over and he fell. The employee was hospitalized with a fractured femur.

Harris Teeter #352

An employee was stocking and ordering the meat case on the sales floor when he slipped and fell due to water on the floor. The employee was hospitalized with a fractured ankle and required surgery.

Georgetown University

An employee was working on an exhaust fan on the roof when he tripped on a wire and fell to the ground. The employee sustained scrapes on his elbow, and a fractured right knee with a torn ACL. The employee was hospitalized.

United Masonry and Landscaping, LLC

An employee was climbing a scaffold when he slipped and fell 10 to 15 feet to the ground. The employee was hospitalized with a fractured ankle.