105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Cleco Corporate Holdings, LLC

Struck by powered vehicle-nontransport, unspecified · Soreness, pain, hurt-nonspecified injury

Federal OSHA recorded a severe workplace injury at Cleco Corporate Holdings, LLC, 1511 Academy Drive, EUNICE, LOUISIANA 70535 on — Soreness, pain, hurt-nonspecified injury, affecting the toes(s), toenail(s).

An employee's right foot was struck by an outrigger, injuring the big toe and second toe and requiring hospitalization.

Hospitalized Toes(s), toenail(s) Boom truck, bucket or basket hoist truck

Auto Run USA

An employee was performing maintenance on conveyor lines when he jumped out of the way of a moving rail-guided vehicle (RGV). He landed in the conveyor line and was then bumped by the rail-guided vehicle, causing him to strike an angle iron that was a part of a stationary conveyor. His stomach was crushed and the employee sustained a laceration to the abdomen.

Ingram Ready Mix, Inc.

An employee was troubleshooting a hydraulic piston on the wheels of a semi-trailer dump truck. The piston released and caused the trailer to move, crushing the employee's leg. The employee sustained fractures and contusions.

Kinder Morgan Port Manatee Terminal LLC

An employee was working on the attachment securing mechanism of a skid steer when their hand was caught by the mechanism. The employee was hospitalized with fractures and lacerations to three fingers on the left hand.

Dragados - Pulice Joint Venture

An employee was spreading the forks on a parked forklift when he was struck in the face by one of the forklift tines, resulting in a contusion.

Downrite Engineering Corp.

An employee was releasing a chain to open the rear flap of a dump truck when three of their fingers got caught between the chain and the truck, resulting in crush injuries.

QB Corporation

An employee was performing troubleshooting and maintenance on one of the generators that feed the RF line for glue-laminated timber (glulam) beam production. He was reattaching the outer panel of the generator. A circuit was completed and the employee was electrocuted by the generator and sustained burns. The employee was hospitalized.

Oncor Electric Delivery Company, LLC

An employee was utilizing a utility task vehicle (UTV) to patrol a 138 kV transmission line in a right-of-way. The UTV drove into a washout hole that was approximately 6 feet deep and obstructed by vegetation. The employee sustained a dislocated shoulder, a fractured left humerus, back pain, and a strained ankle. He was hospitalized.

Central Maine Power Company

A crew of employees were working to replace a utility pole that was broken by a motor vehicle accident. As the crew was removing equipment from the broken pole, part of the pole broke, fell on the injured employee, and rolled over him. The employee sustained two broken shoulders, multiple broken ribs, and a damaged lung that required hospitalization and surgery.

Ameren Illinois - Sparta Operating Center

An Ameren lineman was making secondary voltage connections in a pad-mounted residential feed transformer. The lineman contacted an energized lead bushing, sustained an electrical shock, and was hospitalized.

Satilla EMC

An employee was checking voltage on a meter. There was an arc flash, and the employee suffered burns to both hands.

Kisatchie Midnight Express

A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.

CHRISTUS St. Frances Cabrini Hospital

A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.

Jean Simpson Personnel Services, Inc.

A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.

Calvary Industries Inc

An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.