Struck by powered vehicle-nontransport, n.e.c. · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at JL Taylor Company, 15035 Berkshire Industrial Parkway, MIDDLEFIELD, OHIO 44062
on — Amputations, affecting the finger(s), fingernail(s), unspecified.
Final narrative
An employee was lowering the lift gate on a stake truck when his fingers were caught and smashed beneath the closing gate. His left middle finger was partially amputated.
AmputationFinger(s), fingernail(s), unspecifiedTruck-motorized freight hauling and utility, n.e.c
An employee was going to fill a pallet with items from the warehouse. He was reaching for the handle of the pallet jack but unintentionally grabbed the throttle, causing the pallet jack to move and pin him against another pallet jack. The employee sustained a leg fracture.
An employee was loading merchandise onto rolling containers that were on a remote-operated order picker. While reorganizing merchandise to prevent top loading, the employee's wireless control device contacted a container and caused the order picker to move forward. The employee's right ring finger was caught between two containers and was amputated above the first knuckle.
The injured employee was operating an elevator at a construction site. He went from the tenth floor to the eleventh floor with a plumber and a scissor lift in the elevator. The plumber was using a remote to operate the scissor lift. As the scissor lift was exiting the elevator, a pipe that was on the scissor lift struck the injured employee's chest. The employee was hospitalized.
An employee was dismantling the engine from a vehicle. The vehicle slid off the loader and struck the employee, pushing him into his toolbox. The employee sustained a broken jaw.
More severe injuries in this industry (NAICS 238210)
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.