Struck by dislodged flying object, particle · Fractures and other injuries, n.e.c.
At a glance
Federal OSHA recorded a severe workplace injury
at ADM Grain River System, Inc., 11079 Highway 18, AMA, LOUISIANA 70031
on — Fractures and other injuries, n.e.c., affecting the multiple head locations.
Final narrative
An employee was performing maintenance on a belt. He placed a 36-inch pipe wrench on the belt while it was out of service. When he turned the belt back on, the wrench flew off and hit him, causing head trauma and multiple facial and nose fractures.
HospitalizedMultiple head locationsWrenches-nonpowered
More severe injuries at ADM Grain River System, Inc.
An employee was operating a crane to load grain onto an ocean-going ship when a hydraulic hose failed and caused a fire after contacting a muffler. The employee exited the cab of the crane and landed on a catwalk, breaking the right leg.
An employee was tossing a damaged toilet into a compactor. The toilet bounced off the compactor and lacerated the employee's right wrist, cutting an artery and tendon.
An employee was operating a hydraulic jack to bend a frame when the jack came loose and struck the employee. They were hospitalized for a spleen injury.
A truck had been towed into the shop with a flat tire and a blown airbag. An employee checked the tire for damage and was airing the tire. The employee was installing the valve core when the bead slipped off the rim. Air escaped, and the aluminum wheel struck the employee's head and face. The employee became unresponsive and was bleeding.
On December 14, 2023, at 8:40 p.m., three employees were inspecting milling machines for startup. A few of the sleeves on the mill drum needed to be changed out. The injured employee was trying to input a sleeve on the mill drum using a hammer. The hammer hit the edge of the drum, which caused a metal piece to splinter off and strike the employee's cheek just below the left eye. The metal splinter embedded in the back of their eye socket, resulting in pain, swelling, and bleeding that required hospitalization.
An employee was pushing a line of carts into a vestibule when the door cable snapped and struck his right ankle. The employee suffered a fracture that required surgery and hospitalization.
More severe injuries in this industry (NAICS 424510)
An employee was preparing to unjam an auger shaft while standing on a forklift-elevated, job-made platform. The employee's wrench slipped off the equipment, causing them to lose their balance and fall. The employee landed on the ground 14 feet below and suffered fractures to the orbital bone, left elbow, and lower back.
An employee was walking past a crossover conveyor when a ramp came down and hit them in the back. The employee sustained a broken back vertebra, as well as a concussion, and was hospitalized.
An employee bent over to pick up a rubber mat from the ground. When he grabbed the corner of the mat, a rattlesnake hidden under it bit his left middle finger near the first knuckle. He was hospitalized.
An employee had been cleaning a grain bin. He walked across the bin and his left foot contacted an unguarded floor auger, resulting in severe lacerations to the foot. The auger was not locked out/tagged out at the time.
On September 23, 2025, an employee was monitoring a feed roller when they tripped and their right hand contacted the roller. The employee was hospitalized and their right hand was amputated at the wrist.
A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.
A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.
A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.
An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.