105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Superior Plus Energy Services Inc.

Other fall to lower level 6 to 10 feet · Second degree chemical burns and corrosions

Federal OSHA recorded a severe workplace injury at Superior Plus Energy Services Inc. , Ontario Beash State Pkwy median Access Spot, HAMLIN, NEW YORK 14464 on — Second degree chemical burns and corrosions, affecting the nonclassifiable.

An employee was delivering propane to a tank when the pressure relief valve popped off due to pressure buildup and struck the employee. The liquid propane then sprayed the employee, who fell approximately 10 feet from the equipment to the decking floor. The employee sustained multiple contusions, lacerations, and first and second degree burns.

Hospitalized Nonclassifiable Nonclassifiable

Superior Plus Energy Services Inc.

At approximately 11:45 AM, an employee was taking a break after having set up a propane delivery site (staging tanks) at a customer location. The employee was having difficulty speaking and had a headache. The employee was hospitalized for heat stroke caused by high temperatures.

Superior Plus Energy Services Inc.

An employee was connecting testing equipment to an underground propane storage tank's regulator. Liquid propane sprayed from the tank's relief valve onto the employee's face and neck. He suffered cryogenic burns to the face, neck, and mouth.

Superior Plus Energy Services Inc.

An employee fell approximately three feet off a lift gate while trying to stabilize forklift propane fuel cylinders, resulting in a broken jaw.

View Superior Plus Energy Services Inc. 's full OSHA safety record →

Petroleum Service Corporation

An employee was preparing a tank car for loading while chipping away solidified product in the manway opening of the tank car. A pressure noise within the tank car startled the employee, causing him to stumble backward and fall approximately 10 feet over the guard railing at the chemical loading rack to the ground. The employee suffered fractured vertebrae, a fractured right wrist and ankle, and a dislocated jaw.

Absolics Inc.

An employee was installing an electrical tray remover from a ladder. As he was descending, his missed a step and fell 6-7 feet to the floor. The employee suffered a head injury.

American Residential Products, Inc.

Two employees were installing spray foam insulation in the attic of a new residential construction. The injured employee fell 8 feet from an A-frame ladder to the floor. The employee suffered lacerations, abrasions, and a head injury.

Berkheimer Maintenance

An employee was on a raised platform attaching wires to electrical boxes. The employee fell approximately 8 feet to the floor below and struck an exit sign on the way down, resulting in an injury to his face.

High-Tec Industrial Services, Inc.

An employee was in a forklift man basket fixing a garage door opener when they fell approximately 8 feet to the concrete ground below. The employee suffered head and back injuries as well as kidney bruising.

Ferrellgas, L.P.

An employee was connecting a hose to fill a propane cylinder. The flow of propane was activated when the filler nozzle was partially connected to the cylinder. The nozzle detached from the cylinder valve, causing expanding liquid propane to release through the nozzle. This caused the employee to lose his balance, spin, become entangled in the hose, and fall. He struck his head on the ground and suffered fractures to the temple and cheekbones, a laceration on the forehead, and a brain bleed. The employee was hospitalized.

Amerigas Propane, Limited Partnership

An employee was filling a motor fuel cylinder from a bobtail. When he opened the handle on the fill nozzle it popped off the filler valve and pushed him back into a rack where he struck his head on a cylinder cage. He sustained a laceration to the back left side of his head. While working to wrestle the hose to the ground, he sustained burns from liquid propane on the right side of his chest and right arm, and sustained minor burns on the left side.

AMERIGAS PROPANE GP, LLC

An employee had been refueling empty propane tanks at a site. He drove back to the bulk plant facility and began to feel ill. The employee sustained dehydration due to heat.

Ferrellgas, L.P.

An employee was pumping liquid propane from a propane delivery truck to a storage tank. After the transfer was completed, the employee closed the valves and disconnected the transfer hose. During the transfer, the liquid propane auto-refrigerated the riser pipe of the storage tank and that delayed the vaporization of the propane. Upon reaching a higher temperature, liquified propane began rapidly expanding. Liquid propane then discharged from the pipe and contacted the employee, causing cold burns. The employee was hospitalized for second-degree burns to their torso and arms.

Region Energy

An employee was delivering propane to a customer when he heard a pop in his lower back. The employee was hospitalized with a back injury.

Garden Angels New York LLC

An employee was cleaning leaves with a backpack blower when he fell from a ladder, resulting in injuries to his head, neck, and back.

Cashless Tolling Constructors

An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.

NYU Langone Hospital-Brooklyn

An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.

VILLAGER CONSTRUCTION, INC.

An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.