Caught in running equipment or machinery, unspecified · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at The Amalgamated Sugar Company, LLC, 2320 ORCHARD DRIVE EAST, TWIN FALLS, IDAHO 83301
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
An employee was attempting to change a blade on a knife straightener when the blade amputated half of the first digit on the employee's right hand. The knife straightener was operating at the time of the incident.
AmputationFinger(s), fingernail(s), n.e.c.Special process machinery, unspecified
More severe injuries at The Amalgamated Sugar Company, LLC
An employee was crushed between two sections of corrugated pipes being pushed by a loader, suffering a cracked pelvis, bruised spleen, and broken tailbone.
An employee was using a steel rod to break up sugar lumps in a silo when the rod was pulled in by the silo's screw conveyor and the employee's right hand was caught in the rod handle, amputating the right pinky, ring, and middle fingers.
On December 19, 2023, an employee was setting up a copper wire drawing machine when his left ring finger was pinched between a copper wire and a machine part. The employee's finger was partially amputated.
An employee was checking the gusset seal on a machine. He moved to the next cross sealer and the machine activated, causing an amputation to a left-hand finger. The employee was hospitalized.
An employee was evaluating a coiling machine to verify that the blade was present inside it. The machine's weld function was activated, and the machine crushed the employee's fingers, resulting in the amputation of the left middle and ring fingers.
An employee was helping change out socks on hard thin juice filters, part of a beet sugar manufacturing operation. While the filter lid was being removed, juice started leaking down the side of the filter. This suggested that the juice was bypassing the seat on the main shutoff valve. While the main shutoff was being checked, the valve was opened and sprayed hot juice on the employee. The employee suffered burns to the left arm, the left ribcage area, the left side of the back, and the left side of the face. The employee was hospitalized.
An employee was removing a beet elevating belt while mechanics were cutting a hole in the center of the belt to install the pulley point using an oscillating tool with a hook blade. The tool popped out of the belt and the tool struck the injured employee in the stomach, resulting in a laceration on the lower left abdomen.
An employee was troubleshooting the precoat/overflow tank when scalding liquid (juice) began to leak out of the tank and contacted the employee. The employee was hospitalized for burns.
An employee was clearing a jam in the bag sealer machine in the warehouse when his right thumb was caught in the belt and pulley, resulting in amputation of the thumb tip.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
An employee was standing on a multi-purpose ladder installing head flashing over a window. Their feet were approximately 6 feet off the ground and three rungs from the top. The employee lost their grip on the drill they were using and the ladder tipped over. The employee fell from the ladder to the ground, resulting in a fractured left wrist, bruised chest, and lacerations to their face and lip.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
An employee was loading a 4-inch wooden door into a pickup truck when he felt a pop in his right side behind his shoulder blade. He was hospitalized later that day and underwent surgery, having suffered a collapsed right lung.