Caught in running equipment or machinery during maintenance, cleaning · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at TROJAN BATTERY COMPANY, LLC, 5174 Minola Drive, LITHONIA, GEORGIA 30038
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
An employee was completing preventive maintenance on a screw conveyor oxide reactor when the machine amputated two of his fingers and partially amputated a third finger.
An employee was using a 36-inch-long tool to clear battery plates out. The tool contacted a conveyor, which pulled the employee's right hand too close to the opening to an oven. The tip of his index finger was amputated.
An employee was attempting to repair a slide on a grid casting machine when the die closed and caught his gloved hand. His left thumb was pinched in the mold, resulting in a soft tissue amputation to the left thumb tip (no bone loss).
An employee was scraping paste from a chute into a hopper when his scraping tool fell into the hopper. As he was attempting to retrieve his tool, the mechanical stirring paddle inside the hopper contacted his hand, injuring his finger.
Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.
An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.
An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 335912)
An employee was demonstrating how to disassemble and reassemble a metal filter unit from the cathode powder transfer line. During the open/close operation of an automated valve, the employee s latex glove became caught. The employee sustained a partial amputation to the left index finger.
On March 5, 2025, an employee was pushing an 8-foot x 12-foot x 2-foot electrical panel weighing 3 tons into the electrode room when the panel tipped over, striking his leg. The employee sustained a fractured right femur.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.