Struck by falling object or equipment, n.e.c. · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Georgia Power Company, 2703 Walker St., COLUMBUS, GEORGIA 31903
on — Fractures, affecting the multiple trunk locations.
Final narrative
An employee was struck by a falling tree limb while standing on a sidewalk in preparation for powerline work. He suffered an L1 vertebra fracture and seven broken ribs.
An employee had been preparing material for a lineman at a jobsite and was pulling up wire on a hand line. The employee began to feel ill, suffering from heat illness.
An employee was participating in lineman training outdoors when he felt ill and had cramps in his hands. The employee was hospitalized due to heat stress.
On March 21, 2024, an employee was working on a pad-mounted transformer using a drill that came into contact with a live line causing an arc flash that burned the right side of his neck and an eye.
An employee was moving a piece of an I-beam for welding when it rolled off the cribbing. The employee went to catch it when it fell and crushed the employee's finger, resulting in a partial amputation.
An employee was helping to disassemble large reels used to store steel wire when a 264-pound flange from the reel fell over onto the employee's left leg. The employee sustained multiple fractures to their leg and ligament injuries to the lower leg.
The injured employee was putting away materials on the warehouse floor as a co-worker was pushing a pallet onto a nearby shelf. The pallet knocked another pallet forward, causing it to fall onto the injured employee's shoulders. The employee suffered fractures in their right and left knees and ankles.
Employees were moving a single man lift into a building and reclining the lift to position it to fit through the door. The lift shifted and fell, causing the employee to sustain fractures to the left tibia and fibula. The employee was hospitalized and had surgery.
An employee was moving a light tower so it could be hitched to a truck. He grabbed the tongue of the trailer hitch on the light tower to slide it to the left. The tongue jack fell off, causing the light tower tongue to drop on the employee's right hand. The employee's middle fingertip was amputated.
More severe injuries in this industry (NAICS 221122)
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.
An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.
A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.
An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.
An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.