PECO Energy Company

Fall on same level, n.e.c. · Fractures

Federal OSHA recorded a severe workplace injury at PECO Energy Company, 2610 S Columbus Blvd, PHILADELPHIA, PENNSYLVANIA 19148 on — Fractures, affecting the hip(s).

While reaching for a paper towel dispenser, an employee lost balance and fell to the floor, suffering a broken left hip. The employee was hospitalized.

Hospitalized Hip(s) Floor, n.e.c.

PECO Energy Company

Employees were installing a gas main on a residential property. The injured employee was directing a tri-axle as it was reversing toward a backhoe when the tri-axle struck the backhoe. The backhoe shifted off the curb and struck the employee's leg, fracturing it.

PECO Energy Company

An employee was walking across the jobsite when they slipped on black ice and fell to the ground. The employee was hospitalized with three fractured ribs.

PECO Energy Company

An employee was preparing to "prove phases" by sending power to another underground section. The employee entered a manhole and contacted an energized conductor via a grounded probe. This caused a flashover event and the employee sustained electrical shock and burns to face.

PECO Energy Company

An employee was working underground when he began experiencing symptoms of heat exhaustion. The employee was hospitalized for dehydration and heat illness.

PECO Energy Company

An employee climbing a pole during training activities became ill and was later hospitalized for heat stress.

View PECO Energy Company's full OSHA safety record →

Abbott-Action, Inc.

An employee was pulling on a bale of corrugated cardboard boxes that were on a conveyor. The straps on the bale failed and the employee fell to the floor. The employee was hospitalized and required surgery for a fractured femur and/or hip.

United States Postal Service

On December 27, 2023, an employee was delivering mail to an apartment complex when their knee gave out and they fell to the ground. The employee was hospitalized with a left tibia fracture.

Millennium Mat Company

An employee was walking to the inventory cage when her ankle gave out and she fell to the floor. The employee sustained a femur fracture and was hospitalized.

Publix Super Markets, Inc.

An employee was dislodging a pallet that was stuck when boxes of product fell onto them, causing them to fall to the ground. The employee suffered a fractured femur.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.

Cherokee Electric Cooperative

An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.

Centerpoint Energy Houston Electric, LLC

A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.

Public Service Electric & Gas

An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.

Bright Star Solutions, Inc

An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.

Main Line Clinical Labs

An employee was closing a door when the door closed on their right index finger, resulting in a fingertip amputation.

Ardent Mills

An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.

Zimmerman & Herr

An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.

McAneny Brothers, Inc.

An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.

Metz Culinary Management LLC

An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.