Struck by falling object or equipment, n.e.c. · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Hoover Treated Wood Products, 2901 Dixie Wood Dr, PINE BLUFF, ARKANSAS 71602
on — Fractures, affecting the ankle(s) and leg(s), unspecified.
Watch Hoover Treated Wood Products — freeGet an email when a new federal OSHA severe-injury report for Hoover Treated Wood Products is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was cutting plastic bands on a bundle of 36 sheets of plywood that was suspended about 3 to 4 inches on another bundle placed on a rail tram. The employee was standing on the ground while cutting the bands. A forklift driver moved the forklift and the plywood shifted. About 10 to 12 sheets fell onto the employee, causing him to sustain three fractures on the right leg and right ankle.
HospitalizedAnkle(s) and leg(s), unspecifiedPlywood, wood paneling; particle, chip, flake board
More severe injuries at Hoover Treated Wood Products
An employee was moving a piece of an I-beam for welding when it rolled off the cribbing. The employee went to catch it when it fell and crushed the employee's finger, resulting in a partial amputation.
An employee was helping to disassemble large reels used to store steel wire when a 264-pound flange from the reel fell over onto the employee's left leg. The employee sustained multiple fractures to their leg and ligament injuries to the lower leg.
The injured employee was putting away materials on the warehouse floor as a co-worker was pushing a pallet onto a nearby shelf. The pallet knocked another pallet forward, causing it to fall onto the injured employee's shoulders. The employee suffered fractures in their right and left knees and ankles.
Employees were moving a single man lift into a building and reclining the lift to position it to fit through the door. The lift shifted and fell, causing the employee to sustain fractures to the left tibia and fibula. The employee was hospitalized and had surgery.
An employee was moving a light tower so it could be hitched to a truck. He grabbed the tongue of the trailer hitch on the light tower to slide it to the left. The tongue jack fell off, causing the light tower tongue to drop on the employee's right hand. The employee's middle fingertip was amputated.
More severe injuries in this industry (NAICS 321114)
An employee was working from a step ladder and putting grease in a fitting on a cylinder door. His leg was caught between two of the ladder's rungs and the ladder folded up. He fell and broke his leg.
On June 10, 2024, an employee was grinding mulch in a tub grinder. A front end loader was unloading mulch into the tub grinder and ran over his ankle, breaking it and also causing a hairline fracture to his pelvis. He was hospitalized, requiring surgery.
On January 17, 2024, an employee was working on a roller machine when a piece of metal lacerated their right forearm, causing tendon injury. The employee was hospitalized and underwent surgery.
An employee had been warming his hands at a stationary heater near the stacker operator. He was by the rear passenger-side of his parked forklift when another forklift reversed and struck him. His left leg was pinned between the two forklifts and he sustained a fractured fibula.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.
An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.
On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.