Caught in running equipment or machinery during maintenance, cleaning · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at De Beukealer Corp., 228 Industrial Drive north, MADISON, MISSISSIPPI 39110
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
An employee was using a pneumatic butterfly valve to mix flour and sugar when the flour stopped feeding from above. The employee was attempting to clear the flour when the pneumatic valve closed on the employee's right-hand fingers, resulting in a fingertip amputation and a right ring finger amputation.
HospitalizedAmputationFinger(s), fingernail(s), n.e.c.Mixers, blenders, whippers-food and beverage
Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.
An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.
An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 311821)
An employee was using an air hose to blow built-up dough off the rollers under the cutting apron on a conveyor belt line. The air stopped working and they went to manually remove the dough when their right hand was pulled into the pinch point between the apron and roller. The employee was hospitalized with a fracture to their right forearm that required surgery.
An employee was conducting maintenance work on an stainless steel auger feeder (flexible screw conveyor) in the seasoning room. The lower end of the feeder came loose from the hopper. The employee lifted the auger to position it when the auger feed initiated and energized the auger. His hands were pulled into the auger, resulting in hospitalization with a partial amputation of the right thumb.
An employee was walking down a flight of stairs from a catwalk to a production area. The employee missed a step, fell down the stairs, and suffered broken ribs.
An employee was troubleshooting a packaging machine. While adjusting the air pressure of the machine, the forming head triggered and the lever struck his left index finger. The finger was cut and the fingertip was amputated.
An employee was retrieving a pen that fell under a cross conveyor when her right arm became entrapped between the conveyor belt and the underside drive roller. Her forearm was fractured.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.
An employee was going into a trailer to mark product for shipment and the trailer pulled away from the dock. The employee fell out of the trailer, contacted the dock plate, and then fell to the ground. The employee was hospitalized with a punctured lung, fractured ribs, and contusions.
An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.
An employee was operating a gas tugger to lift metal sheeting. His left hand was pulled into the pulley, which crushed his left thumb, resulting in avulsions and other tissue damage. He was hospitalized and required surgery.