105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

E-J Electric T & D LLC

Struck by dislodged flying object, particle · Fractures

Federal OSHA recorded a severe workplace injury at E-J Electric T & D LLC, 125 Shavertown RD., NEW PALTZ, NEW YORK 12561 on — Fractures, affecting the jaw, chin.

An employee was boring a hole for a power/telephone pole using a utility truck with an auger bit. The employee finished the hole and was stowing the auger bit when the safety cable broke. The auger bit struck the employee, breaking his jaw and causing facial contusions.

Hospitalized Jaw, chin Vehicle and mobile equipment parts, n.e.c.

E-J Electric T&D LLC

An employee was in a bucket truck making electrical connections on primary transmission lines. An arc flash occurred and the employee sustained second-degree burns to the face.

E-J Electric T & D LLC

An employee was hand digging a shallow trench for an electrical conduit installation. While digging the trench, the employee encountered tree roots. To remove the tree roots, he cut partially through the roots with his personal utility knife. After cutting the majority of the exposed roots, he placed the utility knife outside the trench. He then attempted to pull the remaining roots and the sudden release of the roots caused his arm to rotate backwards, allowing his left wrist to contact the utility knife blade and suffer a laceration.

View E-J Electric T & D LLC's full OSHA safety record →

Lowe's Home Improvement

An employee was tossing a damaged toilet into a compactor. The toilet bounced off the compactor and lacerated the employee's right wrist, cutting an artery and tendon.

S & J Construction, LLC

An employee was operating a hydraulic jack to bend a frame when the jack came loose and struck the employee. They were hospitalized for a spleen injury.

RMVK Enterprise, INC.

A truck had been towed into the shop with a flat tire and a blown airbag. An employee checked the tire for damage and was airing the tire. The employee was installing the valve core when the bead slipped off the rim. Air escaped, and the aluminum wheel struck the employee's head and face. The employee became unresponsive and was bleeding.

Dustrol Inc.

On December 14, 2023, at 8:40 p.m., three employees were inspecting milling machines for startup. A few of the sleeves on the mill drum needed to be changed out. The injured employee was trying to input a sleeve on the mill drum using a hammer. The hammer hit the edge of the drum, which caused a metal piece to splinter off and strike the employee's cheek just below the left eye. The metal splinter embedded in the back of their eye socket, resulting in pain, swelling, and bleeding that required hospitalization.

WalMart #436

An employee was pushing a line of carts into a vestibule when the door cable snapped and struck his right ankle. The employee suffered a fracture that required surgery and hospitalization.

QB Corporation

An employee was performing troubleshooting and maintenance on one of the generators that feed the RF line for glue-laminated timber (glulam) beam production. He was reattaching the outer panel of the generator. A circuit was completed and the employee was electrocuted by the generator and sustained burns. The employee was hospitalized.

Oncor Electric Delivery Company, LLC

An employee was utilizing a utility task vehicle (UTV) to patrol a 138 kV transmission line in a right-of-way. The UTV drove into a washout hole that was approximately 6 feet deep and obstructed by vegetation. The employee sustained a dislocated shoulder, a fractured left humerus, back pain, and a strained ankle. He was hospitalized.

Central Maine Power Company

A crew of employees were working to replace a utility pole that was broken by a motor vehicle accident. As the crew was removing equipment from the broken pole, part of the pole broke, fell on the injured employee, and rolled over him. The employee sustained two broken shoulders, multiple broken ribs, and a damaged lung that required hospitalization and surgery.

Ameren Illinois - Sparta Operating Center

An Ameren lineman was making secondary voltage connections in a pad-mounted residential feed transformer. The lineman contacted an energized lead bushing, sustained an electrical shock, and was hospitalized.

Satilla EMC

An employee was checking voltage on a meter. There was an arc flash, and the employee suffered burns to both hands.

Garden Angels New York LLC

An employee was cleaning leaves with a backpack blower when he fell from a ladder, resulting in injuries to his head, neck, and back.

Cashless Tolling Constructors

An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.

NYU Langone Hospital-Brooklyn

An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.

VILLAGER CONSTRUCTION, INC.

An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.