Caught in running equipment or machinery, unspecified · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Irving Forest Products, Inc., 24 Hall Hill Road, DIXFIELD, MAINE 04224
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was removing a broken board from a green chain when his hand was caught in a pinch point. He suffered a fingertip amputation.
AmputationFingertip(s)Metal, woodworking, and special material machinery, unspecified
More severe injuries at Irving Forest Products, Inc.
An employee was removing a slab of wood from a chip conveyor when the wood became caught in the drive chain. The employee's hand was pinned against the conveyor support I-beam, resulting in a crushed right thumb and palm.
A maintenance employee was conducting maintenance on the left side of a gang saw while other employees were changing a saw blade on the right side of the equipment. Once the saw blade was attached, the equipment began operating and the maintenance employee was caught in a pinch point, suffering injuries to the left hip and pelvis.
On December 19, 2023, an employee was setting up a copper wire drawing machine when his left ring finger was pinched between a copper wire and a machine part. The employee's finger was partially amputated.
An employee was checking the gusset seal on a machine. He moved to the next cross sealer and the machine activated, causing an amputation to a left-hand finger. The employee was hospitalized.
An employee was evaluating a coiling machine to verify that the blade was present inside it. The machine's weld function was activated, and the machine crushed the employee's fingers, resulting in the amputation of the left middle and ring fingers.
An employee was repairing a photo eye on the infeed roll case when they dropped a tool. The employee went to grab the tool and his fingers contacted the chain and sprocket of the infeed roll case. His fingers were pulled into the pinch point and the fingertips were crushed, resulting in amputation of one fingertip.
An employee was troubleshooting dispersing equipment. A belt and pulley system was energized, and the moving belt caught the employee's right ring finger. He suffered a partial amputation at the first knuckle, below the nail.
An employee was cleaning the photo eye sensors of a piece of equipment between the saw that cuts lumber into lengths and boards. The employee stepped on a metal grate that gave way and fell 8-10 feet. The employee was able to remove himself from the conveyor. His tibia was fractured just below the knee.
While refilling a lubricant tank, an employee observed that a pump was not operating correctly. While troubleshooting the issue, the employee reached toward the back of the pump to check for proper airflow. Their left index finger contacted moving components in the pump's piston mechanism, resulting in partial amputation of the fingertip.
A crew was installing drilled micropiles alongside an outdoor covered deck foundation. The injured employee was working the front of the drill when a loose section of casing dropped onto the tip of a rig wrench and pulled the wrench down to an embedded casing. The employee's left little finger was caught between the rig wrench and the embedded casing and was amputated above the top knuckle.
Two employees were working to change a tire on a mobile slasher saw. The slasher weighs around 2,000 pounds and is towed. Employee 2 was lifting the saw while the injured employee was placing a block of wood under the frame for support. The slasher then lowered onto the block and the injured employee's left thumb was crushed between the slasher frame and the wood block, leading to an amputation at the first knuckle.
An employee was using a crane to move a 44-foot, 3,343-pound I-beam. As the beam was moving west, it straightened out (north to south), beginning to swing south toward the northwest corner of a building. The crane then sent the beam southward, directly toward the corner of the building. The beam caught the tips of the employee's left index, middle, and ring fingers against the building. The last joints of the middle and ring fingers were amputated, and the last joint of the index finger was partially crushed.
An employee was standing on a step stool, removing the nuts and bolts from the frame of a solar panel that was being replaced. The employee's cheek made contact with a connector with damaged insulation. The employee was shocked, briefly lost consciousness, and fell to the ground, suffering an injury to the left shoulder.