Compressed or pinched by shifting objects or equipment · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at RESILUX AMERICA, LLC, 265 JOHN BROOKS RD., PENDERGRASS, GEORGIA 30567
on — Fractures, affecting the hand(s), unspecified.
Final narrative
An employee was pulling a mold out of a machine when the mold pinned the employee's hand against the machine, causing a laceration and fracture to the hand that required surgery and hospitalization.
An employee was watching as a technician worked with a machine. The machine's parts were manually moved while the employee's hand was inside the machine, and his fingertip was amputated. The incident took place during a training activity.
An employee was operating a forklift and unloading a truck. After the truck was unloaded, the employee got off the forklift and proceeded to adjust the dock plate with a hook tool. The dock plate slipped and the employee went to adjust the plate with their hand when their left middle finger got caught. Their finger was amputated above the first joint.
An employee was rotating a carbide granulator blade when his finger was caught between the blade and a stationary part of the machine. The employee's right middle finger was partially amputated and they suffered an avulsion to the right ring fingertip.
An employee was using a CNC metal lathe machine in manual mode to check that the thread blocking tool made contact with the jaws. As the employee was manually spinning the spindle, his index fingertip was crushed between the spindle's jaws and the grooving insert, resulting in a fingertip amputation.
During a material handling operation, an employee's fingertip was caught under an air conditioning unit as the unit was lowered onto a cart. The employee's fingertip was amputated.
An employee was removing a bolt from a tractor hub when their right index finger was caught between the hub and the frame. The employee's fingertip was crushed and the employee was hospitalized.
More severe injuries in this industry (NAICS 326160)
An employee was watching as a technician worked with a machine. The machine's parts were manually moved while the employee's hand was inside the machine, and his fingertip was amputated. The incident took place during a training activity.
On October 14, 2025, an employee was on a step platform showing another employee the support bracket for a blow pin assembly on a blow molding machine that needed repaired. The blow pin assembly came up and pinched the injured employee's right middle finger, resulting in a broken finger and a laceration to the top of the hand.
On August 22, 2025, an employee was helping to move a 700-pound compressor cylinder cap head into position to slide down the bolt holes onto the bottom half of the cylinder. When a bolt hole aligned, his left index fingertip was caught in it. The cap came down and amputated the fingertip.
A maintenance employee was working on a conveyor when his thumb was caught in the chain/sprocket area causing an amputation to the thumb tip. The machine was running at the time of the incident.
On March 20, 2025, at approximately 11:02 AM, an employee was shrink wrapping a pallet when he lost his balance and fell to ground. The employee sustained a hip and leg injury that required hospitalization and surgery.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.