Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31

PPL Electric Utilities

Fall from collapsing structure or equipment 11 to 15 feet · Fractures

Federal OSHA recorded a severe workplace injury at PPL Electric Utilities, 398 Center Street, SCRANTON, PENNSYLVANIA 18501 on — Fractures, affecting the multiple body parts, n.e.c..

Watch PPL Electric Utilities — free Get an email when a new federal OSHA severe-injury report for PPL Electric Utilities is published. One employer, no account, unsubscribe in one click.

On December 19, 2019, an employee was working inside an electrical vault. As the employee tried to climb an extension ladder, the ladder failed and the employee fell about 15 feet, suffering a broken pelvis and two broken wrists.

Hospitalized Multiple body parts, n.e.c. Extension ladders

PPL Electric Utilities

An employee tripped while walking out of a building and fell forward into a door. The employee suffered facial injuries, a dislocated shoulder, and a broken foot.

PPL Electric Utilities

Two employees were replacing a cover on a compact trench system. While they were dropping the cover in, one employee's left middle and ring fingers were pinched. Both fingers were broken, and the middle fingertip was amputated. The employee underwent surgery.

PPL Electric Utilities

On January 29, 2020, at approximately 10:50 a.m., an employee was setting up equipment in preparation for cable pulling when his finger made inadvertent contact with the duct dog (cable pulling equipment), resulting in a left pinky fingertip amputation.

PPL Electric Utilities

On August 17, 2017, at approximately 10:45 AM, an employee was attempting to hang a 3-day notice on a customer's residence when she was attacked by a dog. The dog bit and amputated her right pinky fingertip.

View PPL Electric Utilities's full OSHA safety record →

Midday Constructors Inc.

An employee was removing a safety railing from a stairwell. The 2x10 plank they were standing on gave way and the employee fell approximately 12 feet to a lower level, resulting in fractures.

BEYEL BROTHERS, INC.

An employee was climbing a ladder to get to the top of a container. The ladder collapsed and the employee fell 13 feet to the concrete floor, sustaining a fractured pelvis and tailbone.

CTL Group Inc.

An employee was on a roof when the material under his feet gave way. He fell 12 feet, suffering an injury to back vertebrae and a dislocated shoulder.

Filter Kleen Environmental

Two employees were cleaning the ducts on top of a pipe. The pipe gave way and the employees and the pipe fell 15 feet. The pipe landed on one employee's leg, resulting in a fracture in three places and hospitalization. The other employee was not injured.

Tri-State Roofing & Sheet Metal Company of Ohio

An employee was walking on the roof deck performing roofing work when the deck collapsed. The employee fell approximately 13 feet to the ground below, resulting in fractures and bruising to the hips, head, and chest.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.

Cherokee Electric Cooperative

An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.

Centerpoint Energy Houston Electric, LLC

A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.

Public Service Electric & Gas

An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.

Bright Star Solutions, Inc

An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.

Main Line Clinical Labs

An employee was closing a door when the door closed on their right index finger, resulting in a fingertip amputation.

Ardent Mills

An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.

Zimmerman & Herr

An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.

McAneny Brothers, Inc.

An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.

Metz Culinary Management LLC

An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.