Contact with hot objects or substances · Second degree heat (thermal) burns
At a glance
Federal OSHA recorded a severe workplace injury
at Nustar Energy, LP, 201 Dock Road, TEXAS CITY, TEXAS 77590
on — Second degree heat (thermal) burns, affecting the multiple body parts, n.e.c..
Watch Nustar Energy, LP — freeGet an email when a new federal OSHA severe-injury report for Nustar Energy, LP is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee sustained second degree steam burns to his upper right arm and right torso while operating a steam hose on a railcar.
HospitalizedMultiple body parts, n.e.c.Steam, vapors-nonchemical
An employee connected a steam line to a hose to clean equipment when the fitting broke loose. They were struck by steam in the left inner thigh, resulting in burns that required hospitalization.
An employee was making tea when she noticed tea grinds were collecting on the side and water was no longer dripping through the funnel. The employee was checking the funnel when boiling water and tea grinds spilled onto the left side of her body. The employee sustained burns to her neck, back, and arm.
An employee had turned off the ball valve on a waterpipe system and was removing the plug when the coupling system attached to the strainer came apart. Hot water sprayed on his arm and back, resulting in first- and second-degree burns that required surgery.
An employee was using a shovel to remove waste vermiculite from molten zinc. The metal had been placed in a bin and partially hardened. The employee broke through the partially hardened metal; still-molten metal flowed to the employee's steel-toed right boot and entered through the cloth boot tongue. The employee suffered a third-degree burn to the right foot and was hospitalized.
More severe injuries in this industry (NAICS 486110)
An employee was installing a belt on the regeneration fan at the facility when their left little finger was caught between the fan belt and motor sheave, resulting in a fingertip amputation.
An employee was monitoring the excavation of a 30-inch valve and the pipeline pressure. The employee started getting light-headed, short of breath, and hot. The employee was hospitalized with dehydration.
A valve stem had been stood up against the blades of a forklift so an employee could take a measurement. It slid down the forklift fork, striking the employee's left hand and partially amputating the index fingertip.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.