Pedestrian struck by vehicle in nonroadway area, unspecified · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at The Anderson Company LLC, 950 S. Capitol Street SE, WASHINGTON, DISTRICT OF COLUMBIA 20003
on — Fractures, affecting the ankle(s).
Final narrative
An employee was struck by the tracks of a mini-excavator and sustained a fractured ankle.
An employee was walking back to her workstation. A forklift reversed a short distance, then completed a U-turn and struck her, running over her lower extremities. She was hospitalized with a broken ankle.
An employee was training on a jockey truck. Upon stepping out of the truck, the employee was struck by a rubber tire gantry crane, resulting in amputations of the right leg above the knee and left leg below the knee.
An employee was standing at the rear of a double pallet jack. Another double jack approached, and the employee's lower leg was caught between the two pieces of equipment. He suffered a broken tibia and fibula.
An employee was unloading large material bags on a loading dock. A forklift tine pinned the employee's foot against a pallet, causing the employee to fall and suffer a broken ankle.
An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.
An employee was assisting the crew with patching and restoring a roadway after the installation of a sewer line. He was helping place and level the blacktop/backfill material over the trench area to bring the road surface back to proper grade. The employee was walking between a forward-moving dump truck and a dirt pile when his right foot was run over by the truck s wheel, causing him to fall. The employee sustained injury to his foot.
An employee was operating a skid steer with a bucket attachment at a demolition site. While driving it to the rear of the property to park it, the employee came into contact with a live electrical transformer unit that was located outside of the facility. The employee sustained electrical burns on his hands extending up to his elbows and a fractured ankle.
An employee was installing a door on a semi-trailer. They were using a forklift to lift the door to the height of the trailer when the door became jammed between the forklift mast and the hinge on the trailer. When the employee went to dislodge the door from the mast, the door fell and crushed their foot. Their big toe was amputated. The employee was hospitalized and their big toe was surgically reattached. The employee's foot and other toes also required surgery.
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was assembling a baker type scaffold. He was beginning to transverse down the scaffold, approximately six feet off the ground, when the scaffold tipped over and he fell. The employee was hospitalized with a fractured femur.
An employee was stocking and ordering the meat case on the sales floor when he slipped and fell due to water on the floor. The employee was hospitalized with a fractured ankle and required surgery.
An employee was working on an exhaust fan on the roof when he tripped on a wire and fell to the ground. The employee sustained scrapes on his elbow, and a fractured right knee with a torn ACL. The employee was hospitalized.