Caught in running equipment or machinery during regular operation · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at AHF Products Inc., 688 Hwy 278 Bypass, WARREN, ARKANSAS 71671
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was cutting wood with a foot-operated knot saw when his hand caught on a splinter and was pulled toward the saw. The employee suffered a laceration to his left-hand middle finger and amputation of the tip of his left-hand index finger.
An employee was using a 20-foot section of galvanized pipe to unclog a section of dust pipe in a baghouse. A tip of the galvanized pipe broke through the clogged section, contacted the relay fan, and rotated, pulling away from the employee's hand and striking the right side of his head. He suffered a laceration and a brain injury.
An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.
An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 321113)
An employee was repairing a photo eye on the infeed roll case when they dropped a tool. The employee went to grab the tool and his fingers contacted the chain and sprocket of the infeed roll case. His fingers were pulled into the pinch point and the fingertips were crushed, resulting in amputation of one fingertip.
An employee was troubleshooting dispersing equipment. A belt and pulley system was energized, and the moving belt caught the employee's right ring finger. He suffered a partial amputation at the first knuckle, below the nail.
An employee was cleaning the photo eye sensors of a piece of equipment between the saw that cuts lumber into lengths and boards. The employee stepped on a metal grate that gave way and fell 8-10 feet. The employee was able to remove himself from the conveyor. His tibia was fractured just below the knee.
While refilling a lubricant tank, an employee observed that a pump was not operating correctly. While troubleshooting the issue, the employee reached toward the back of the pump to check for proper airflow. Their left index finger contacted moving components in the pump's piston mechanism, resulting in partial amputation of the fingertip.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.
An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.
On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.