Other fall to lower level 6 to 10 feet · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Quality Erectors & Sheeters, Inc., 1500 Landmark Drive, COTTAGE GROVE, WISCONSIN 53527
on — Fractures, affecting the lumbar region.
Final narrative
On December 22, 2021, employees were using aerial lifts to install ceiling liner and panels. An employee was working from a raised aerial lift and leaned against the lift's door gate, then fell 8-10 feet to the dirt, gravel and snow-covered ground below. The employee was hospitalized with fractures to their L2 and L4 vertebrae and lung lacerations. Fall protection was not attached at the time.
An employee was preparing a tank car for loading while chipping away solidified product in the manway opening of the tank car. A pressure noise within the tank car startled the employee, causing him to stumble backward and fall approximately 10 feet over the guard railing at the chemical loading rack to the ground. The employee suffered fractured vertebrae, a fractured right wrist and ankle, and a dislocated jaw.
An employee was installing an electrical tray remover from a ladder. As he was descending, his missed a step and fell 6-7 feet to the floor. The employee suffered a head injury.
Two employees were installing spray foam insulation in the attic of a new residential construction. The injured employee fell 8 feet from an A-frame ladder to the floor. The employee suffered lacerations, abrasions, and a head injury.
An employee was on a raised platform attaching wires to electrical boxes. The employee fell approximately 8 feet to the floor below and struck an exit sign on the way down, resulting in an injury to his face.
An employee was in a forklift man basket fixing a garage door opener when they fell approximately 8 feet to the concrete ground below. The employee suffered head and back injuries as well as kidney bruising.
More severe injuries in this industry (NAICS 238120)
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
An employee was standing on the surface of a steel beam about two feet wide. He slipped and fell backward, landing on the concrete ground about 20 feet below. The employee sustained a broken pelvis.
An employee was unloading a rebar delivery from a flatbed, 19-wheel trailer. The employee rigged the load with wire rope chokers. The load was picked up 3-4 feet above the trailer deck by a crane. The load began to swing and the employee grabbed onto it to prevent it from being pushed off the trailer deck. The crane continued to lift the load, and the employee let go so the crane did not lift him to the third story. The employee fell approximately 12 feet to the ground below, resulting in a back injury and fractured vertebrae.
An employee was attaching a steel angle plate weighing (approximately 200 pounds) to the end of a structural member (5,000 pounds) and was supported by dunnage. The dunnage was a crane mat (11 inches tall) with a 4x6 board on top of it and it supported five identical members. The main piece was 30.75 feet long, 37.25 feet tall, and 1 food wide. As the employee slid the piece of metal on top of the member to begin attaching it, the entire member began to tip over. The employee went to stop the main piece from tipping over and it landed on his ankle, fracturing it.
The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
An employee was using a vertical band saw to cut a thick piece of rubber material. While being cut, the material shifted, causing the employee s right hand to contact the moving blade. The employee's thumb was amputated below the knuckle. The employee was hospitalized, undergoing surgery.
A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.
An employee was on a ladder, taking measurements for a new gutter installation. The ladder slipped out from under him and both he and the ladder fell to the ground. He was hospitalized with seven broken ribs and a broken clavicle.
An employee was unloading a truck for a delivery job. While moving boxes in the truck, the employee tripped over a pallet and fell out of the truck to the ground, resulting in four broken ribs.