105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Bell Laboratories, Inc.

Overexertion in pushing, pulling, or turning-single episode · Internal injuries to organs and blood vessels of the trunk

Federal OSHA recorded a severe workplace injury at Bell Laboratories, Inc., 6551 North Towne Road, WINDSOR, WISCONSIN 53598 on — Internal injuries to organs and blood vessels of the trunk, affecting the chest, except internal location of diseases or disorders.

Watch Bell Laboratories, Inc. — free Get an email when a new federal OSHA severe-injury report for Bell Laboratories, Inc. is published. One employer, no account, unsubscribe in one click.

An employee was working at a thermoformer removing a pallet from between a roll tipper and a roll of plastic. The employee suffered a collapsed lung.

Hospitalized Chest, except internal location of diseases or disorders Skids, pallets

Bell Laboratories, Inc.

An employee was cleaning a mixer when their right leg got caught between the rubber paddle and mixer wall. The employee was found unconscious and sustained a crushed artery in the right leg.

Bell Laboratories, Inc.

An employee was clearing a jam in a mill when a bolt fell, catching the employee's finger in the die. The employee sustained an amputation.

Bell Laboratories, Inc.

An employee was walking down concrete steps and caught his heel on the last step falling backwards. Both knees buckled due to the way he landed on his feet. The employee suffered torn patellar tendons in both knees.

View Bell Laboratories, Inc.'s full OSHA safety record →

Athol Memorial Hospital

An employee was pushing a patient in a wheelchair up a ramp when she felt a sudden pain in her middle and lower back, resulting in hospitalization.

XPO Logistics

An employee sustained a hernia while manually pulling on a dock plate that was stuck against a trailer. The employee was hospitalized.

Olive Garden USA

An employee was pushing tables together to seat a party of 20 when he felt a sharp pain and experienced difficulty breathing. The employee was hospitalized for a collapsed lung.

Sam's Club #8269

An employee was walking and pushing a basket with cardboard on it when she felt her left knee crack. The employee's left femur was broken.

Sur Gro Plant Food Co

An employee was tightening a belt on a conveyor when the open-end wrench caught his right ring finger at the distal phalange and amputated it.

Sipcam Agro Solutions LLC

An employee was troubleshooting equipment. Due to an equipment malfunction, the employee fell off a beam that was 12-feet high above a powder mixer. He struck another piece of equipment on the ground level and ended up on the ground, unconscious. The employee was hospitalized with burns to his hands, a brain bleed, and fractures to his wrist, pelvis, and tailbone.

ProPoint Cooperative

An employee was filling an ammonia nurse tank. Ammonia (NH3) released from a valve and contacted the employee's chest. The employee also inhaled ammonia vapors and was hospitalized.

ALBAUGH LLC

An employee was dumping a load of trash from a self-dumping hopper into a roll-off dumpster. The hopper shifted while the load was dumping and pinched the employee's left hand against the forklift forks. The employee's fingertip was amputated.

ALBAUGH LLC

An employee was working on a glyphosate tote line. As she was backing up on a 13-inch-high platform, one of her feet slipped off and she fell backward. Her head struck the floor and she lost consciousness, suffering a skull fracture and a brain bleed.

RG Professional Carpenter, Inc.

The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.

General Thermodynamics, Inc.

An employee was using a vertical band saw to cut a thick piece of rubber material. While being cut, the material shifted, causing the employee s right hand to contact the moving blade. The employee's thumb was amputated below the knuckle. The employee was hospitalized, undergoing surgery.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

Asher Enterprises, Inc.

An employee was on a ladder, taking measurements for a new gutter installation. The ladder slipped out from under him and both he and the ladder fell to the ground. He was hospitalized with seven broken ribs and a broken clavicle.

Consolidated Electrical Distributors Inc.

An employee was unloading a truck for a delivery job. While moving boxes in the truck, the employee tripped over a pallet and fell out of the truck to the ground, resulting in four broken ribs.