Fall through surface or existing opening, unspecified · Fractures and other injuries, n.e.c.
At a glance
Federal OSHA recorded a severe workplace injury
at Axcela, Inc., 2401 South Arkansas Avenue, RUSSELLVILLE, ARKANSAS 72801
on — Fractures and other injuries, n.e.c., affecting the multiple body parts, n.e.c..
Final narrative
An employee was on a roof working to replace a skylight. While receiving equipment from the ground, the employee fell through a skylight to the ground below. The employee sustained injury to the spleen and liver, as well as fractures to their hip, ribs, and an arm. The employee was wearing a harness, but it was not connected at the time of the fall.
An employee was power washing a metal tank from an elevated platform. They fell through a gap between the platform and the tank. The employee landed on the ground and sustained fractures to their ankles and feet.
An employee was installing a metal roof when he stepped on a skylight. The employee fell through the skylight to the ground, resulting in head and shoulder fractures.
An employee was replacing an HVAC unit in a residential home. While he was in the attic space above the garage, the wood he was walking on broke, causing the employee to fall through the sheetrock to the concrete floor below. The employee bumped his head and sustained a shoulder injury as well as a broken ankle.
An employee was putting a tarp on a water tank while standing on a trailer. She lost her footing and fell through the trailer bed, striking the corner of the trailer bed. The employee sustained internal bleeding.
An employee was repairing a sub-floor in a residential house that had water and fire damage. The employee fell through the sub-floor and landed in the basement, resulting in spinal fractures that required hospitalization.
More severe injuries in this industry (NAICS 321113)
An employee was repairing a photo eye on the infeed roll case when they dropped a tool. The employee went to grab the tool and his fingers contacted the chain and sprocket of the infeed roll case. His fingers were pulled into the pinch point and the fingertips were crushed, resulting in amputation of one fingertip.
An employee was troubleshooting dispersing equipment. A belt and pulley system was energized, and the moving belt caught the employee's right ring finger. He suffered a partial amputation at the first knuckle, below the nail.
An employee was cleaning the photo eye sensors of a piece of equipment between the saw that cuts lumber into lengths and boards. The employee stepped on a metal grate that gave way and fell 8-10 feet. The employee was able to remove himself from the conveyor. His tibia was fractured just below the knee.
While refilling a lubricant tank, an employee observed that a pump was not operating correctly. While troubleshooting the issue, the employee reached toward the back of the pump to check for proper airflow. Their left index finger contacted moving components in the pump's piston mechanism, resulting in partial amputation of the fingertip.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.
An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.
On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.