105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Consolidated Edison Company of New York, Inc.

Compressed or pinched by shifting objects or equipment · Amputations

Federal OSHA recorded a severe workplace injury at Consolidated Edison Company of New York, Inc., East 16th Street and Avenue T, BROOKLYN, NEW YORK 11210 on — Amputations, affecting the fingertip(s).

Three employees were installing a section of underground cable. The capstan was engaged to pull in the steel cable with a nylon rope. One of the employees had his left hand on the capstan when the switch was toggled, and his ring finger was pinched between the rope and the capstan. He suffered an amputation to some flesh and the nail.

Amputation Fingertip(s) Drums, pulleys, sheaves

Consolidated Edison Company of New York, Inc.

An employee was struck by and caught between two work vehicles. The employee suffered internal bleeding and a fractured leg. The employee was hospitalized.

Consolidated Edison Company of New York, Inc.

An employee was using a ground and test device on a 13-kilovolt distribution feeder. Thirty minutes after completing the operation, the employee was notified of a burning smell in the vicinity of the feeder. While investigating the burning smell, the employee approached the test set-ups when the input high-voltage test lead failed at the connection point to the block and contacted the employee. The employee was rendered unconscious and was hospitalized for burns.

Consolidated Edison Company of New York, Inc.

An employee was disposing of a switch when her left thumb was caught and amputated between the equipment and the container. The employee's thumb was surgically reattached.

Consolidated Edison Company of New York, Inc.

An employee was descending a ladder when he fell to the ground below. The employee sustained a dislocated shoulder and potential internal injuries.

View Consolidated Edison Company of New York, Inc.'s full OSHA safety record →

TForce Freight

An employee was operating a forklift and unloading a truck. After the truck was unloaded, the employee got off the forklift and proceeded to adjust the dock plate with a hook tool. The dock plate slipped and the employee went to adjust the plate with their hand when their left middle finger got caught. Their finger was amputated above the first joint.

Liveo Research, Inc.

An employee was rotating a carbide granulator blade when his finger was caught between the blade and a stationary part of the machine. The employee's right middle finger was partially amputated and they suffered an avulsion to the right ring fingertip.

Best Pump and Flow

An employee was using a CNC metal lathe machine in manual mode to check that the thread blocking tool made contact with the jaws. As the employee was manually spinning the spindle, his index fingertip was crushed between the spindle's jaws and the grooving insert, resulting in a fingertip amputation.

FORD MOTOR COMPANY

During a material handling operation, an employee's fingertip was caught under an air conditioning unit as the unit was lowered onto a cart. The employee's fingertip was amputated.

Lasseter Tractor Company. Inc.

An employee was removing a bolt from a tractor hub when their right index finger was caught between the hub and the frame. The employee's fingertip was crushed and the employee was hospitalized.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.

Cherokee Electric Cooperative

An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.

Centerpoint Energy Houston Electric, LLC

A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.

Public Service Electric & Gas

An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.

Bright Star Solutions, Inc

An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.

Garden Angels New York LLC

An employee was cleaning leaves with a backpack blower when he fell from a ladder, resulting in injuries to his head, neck, and back.

Cashless Tolling Constructors

An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.

NYU Langone Hospital-Brooklyn

An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.

VILLAGER CONSTRUCTION, INC.

An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.