105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Madix, Inc.

Caught in running equipment or machinery, unspecified · Crushing injuries

Federal OSHA recorded a severe workplace injury at Madix, Inc., 20984 AL Hwy 9, GOODWATER, ALABAMA 35072 on — Crushing injuries, affecting the finger(s), fingernail(s), unspecified.

An employee was working on a brake press when it struck his left hand, resulting in crushed index and ring fingers.

Hospitalized Finger(s), fingernail(s), unspecified Brake presses

Madix, Inc.

An employee was feeding scrap metal into a chipper when his right hand was squeezed against a metal component of the machine. He suffered an amputation to the right index finger at the second joint.

Madix, Inc.

On April 10, 2025, an employee was operating a brake press when two of its dies pinched her left ring and middle fingers. She suffered amputations to both fingertips, just above the fingernails. The machine was guarded with a light curtain at the time of the incident.

Madix, Inc.

An employee was using a forklift to move a piece of angle iron. The angle iron slipped off the forklift and hit the employee's right foot resulting in a toe amputation.

Madix, Inc.

An employee was manufacturing parts on a roll former machine. He went to remove the parts and his right hand became caught between the parts and the guard, resulting in partial amputation of his ring finger.

Madix, Inc.

On March 23, 2023, at approximately 9:00 AM, an employee was operating an automated saw. As the employee went to adjust the coolant sprayers, the rotating blades caught his glove and pulled his hand in, resulting in three left-hand finger amputations.

View Madix, Inc.'s full OSHA safety record →

Service Wire Company

On December 19, 2023, an employee was setting up a copper wire drawing machine when his left ring finger was pinched between a copper wire and a machine part. The employee's finger was partially amputated.

Oriental Trading Company, Inc.

An employee was examining a machine when a part moved up and amputated a fingertip on their left hand.

Fox Packaging

An employee was checking the gusset seal on a machine. He moved to the next cross sealer and the machine activated, causing an amputation to a left-hand finger. The employee was hospitalized.

Ashley Furniture Industries, Inc.

An employee was evaluating a coiling machine to verify that the blade was present inside it. The machine's weld function was activated, and the machine crushed the employee's fingers, resulting in the amputation of the left middle and ring fingers.

ITW Bedford Wire

An employee's right hand was caught in a wire drawing machine, resulting in amputation.

Interlake Mecalux, Inc.

On August 13, 2025, an employee was feeding wire through a junction box to feed a 120-volt circuit near a 480-volt bus duct. The bus duct suddenly combusted, and the employee suffered burns to his left hand and upper body. He was hospitalized.

New England Wire Products Inc.

An employee was operating a brake press and making the final bend on a steel part. Her right middle finger got caught between the part and the top punch as it bent the part upward. The employee sustained a crush injury resulting in amputation of the fingertip.

Madix, Inc.

An employee was feeding scrap metal into a chipper when his right hand was squeezed against a metal component of the machine. He suffered an amputation to the right index finger at the second joint.

OPTO INTERNATIONAL, INC.

An employee was setting up a press brake when the machine was activated and her left middle fingertip was caught between the dies and amputated.

THE CENTURY COMPANIES, INC.

On June 18, 2025, an employee working as a millwork installer was cutting shims using a circular saw. The saw hit a knot in the wood and jumped, cutting the palm of the employee's left hand and causing partial amputations to three fingers. The employee was hospitalized.

Sysco Gulf Coast, LLC

An employee was traveling down the maintenance aisle of a warehouse on a single-pallet front rider jack. The jack malfunctioned, causing the brakes to apply; the employee fell forward onto the concrete warehouse floor. The employee suffered an injury to the left leg and was hospitalized, requiring surgery.

Norflex, Inc.

An employee was operating a metal roller machine to roll a small piece of metal. The employee's right index finger became caught between the metal and the machine, and the fingertip was amputated.

Ampler Pizza II LLC

An employee was shot in the leg with a pistol during an altercation with two people who had entered the store without permission.

Birdsong Corporation

An employee was directing a truck driver to a dump site when the truck's peanut trailer slipped off the kingpin. As the trailer fell, a ladder attached to it lacerated the employee's ear. The employee was hospitalized.

Pilgrims

An employee was unloading a forklift from a trailer to the ground. The employee was climbing down the ladder of the trailer when their foot slipped through one of the rungs, causing them to fall backward onto the forklift forks. The employee was hospitalized for fractured ribs.