Exposure through medical injection · Other or unspecified allergic reactions
At a glance
Federal OSHA recorded a severe workplace injury
at Southern Maine Health Care, 1 Medical Center Drive, BIDDEFORD, MAINE 04005
on — Other or unspecified allergic reactions , affecting the bODY SYSTEMS.
Final narrative
An employee was hospitalized for an allergic reaction to the employer-mandated COVID-19 vaccine.
An employee was preparing to vaccinate sows using a needle-free injection gun. The gun engaged and injected the employee's left palm. The employee experienced an allergic reaction.
An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.
A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.
A crew was installing drilled micropiles alongside an outdoor covered deck foundation. The injured employee was working the front of the drill when a loose section of casing dropped onto the tip of a rig wrench and pulled the wrench down to an embedded casing. The employee's left little finger was caught between the rig wrench and the embedded casing and was amputated above the top knuckle.
Two employees were working to change a tire on a mobile slasher saw. The slasher weighs around 2,000 pounds and is towed. Employee 2 was lifting the saw while the injured employee was placing a block of wood under the frame for support. The slasher then lowered onto the block and the injured employee's left thumb was crushed between the slasher frame and the wood block, leading to an amputation at the first knuckle.
An employee was using a crane to move a 44-foot, 3,343-pound I-beam. As the beam was moving west, it straightened out (north to south), beginning to swing south toward the northwest corner of a building. The crane then sent the beam southward, directly toward the corner of the building. The beam caught the tips of the employee's left index, middle, and ring fingers against the building. The last joints of the middle and ring fingers were amputated, and the last joint of the index finger was partially crushed.
An employee was standing on a step stool, removing the nuts and bolts from the frame of a solar panel that was being replaced. The employee's cheek made contact with a connector with damaged insulation. The employee was shocked, briefly lost consciousness, and fell to the ground, suffering an injury to the left shoulder.