Fall on same level due to slipping · Traumatic injuries and disorders, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at U.S. Army Corps of Engineers, 700, 12th Street NW Suite 900, WASHINGTON, DISTRICT OF COLUMBIA 20005
on — Traumatic injuries and disorders, unspecified, affecting the nonclassifiable.
Final narrative
On September 15, 2022, an employee slipped and fell in a room, resulting in hospitalization.
HospitalizedNonclassifiableFloor, n.e.c.
More severe injuries at U.S. Army Corps of Engineers
A picnic pavilion was being repaired. An employee was on the roof of the pavilion attaching an excavator boom. The boom moved unexpectedly and knocked the employee from the roof. The employee landed on the ground 10 feet below and suffered fractures.
An employee was taking pictures of algae and went to use the ladder when they fell 10 feet onto the cement. The employee sustained a broken leg that required hospitalization.
An employee was cutting metal electrical conduit with a pocket knife. The knife fell, severing the employee's right index finger at the first joint, above the nail.
An employee was working in the forest flagging an area to be harvested. He took a step and his foot slipped on a stick hidden under the leaves, causing him to fall to the ground. He landed on his right foot/lower leg resulting in a fractured tibia.
An employee was inspecting an apartment to ensure it was ready for a new resident to move in. The carpet in the apartment had been recently cleaned and was still wet. As the employee went from the carpet to the tiled floor of the bathroom, they slipped and fell, resulting in a torn left hamstring.
An employee was delivering a letter along a rural carrier route when she stepped on an ice-covered snow drift, slipped, and fell to the ground. The employee sustained a right hip fracture that required surgery.
More severe injuries in this industry (NAICS 238990)
A crew was relocating a dumpster (containing approximately 200 pounds of demolished wire) to access the uninterruptible power supply (UPS) units they were servicing. During movement of the dumpster, a section of carpet tile dislodged from the floor, causing an employee to lose his footing, slip, and fall. He landed on his right wrist, resulting in a fracture.
An employee was cutting a board using a circular saw. The saw pinched, kicked back, and cut the employee's left ring and little fingers. The employee suffered an amputation to the little finger.
An employee was using an aluminum extension ladder to remove gutters at a height of approximately 20 feet. As they were removing the gutters, part of the gutter collapsed and struck the ladder, causing it to move sideways. The employee fell from the ladder and sustained fractures to ribs on the left side and their right forearm.
An employee was using an electric saw to cut a piece of wood for a fence. The saw slipped out of his hand and lacerated his left leg. He was hospitalized.
An employee was erecting a scaffold. A side bracket was not secure. The employee stepped on the bracket to test it and fell 18 feet to the concrete floor resulting in fractures to the ankles and femurs. He was not using fall protection equipment.
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was assembling a baker type scaffold. He was beginning to transverse down the scaffold, approximately six feet off the ground, when the scaffold tipped over and he fell. The employee was hospitalized with a fractured femur.
An employee was stocking and ordering the meat case on the sales floor when he slipped and fell due to water on the floor. The employee was hospitalized with a fractured ankle and required surgery.
An employee was working on an exhaust fan on the roof when he tripped on a wire and fell to the ground. The employee sustained scrapes on his elbow, and a fractured right knee with a torn ACL. The employee was hospitalized.