105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Heatcraft Worldwide Refrigeration

Caught in running equipment or machinery during regular operation · Amputations

Federal OSHA recorded a severe workplace injury at Heatcraft Worldwide Refrigeration, 30 N. Magnolia Rd., TIFTON, GEORGIA 31794 on — Amputations, affecting the finger(s), fingernail(s), unspecified.

The injured employee was inserting a rod into the expander machine in order to build a new coil. The injured employee asked employee 2 to operate the machine while they inserted the rod. While employee 2 was lowering the header guide, the injured employee was leaning against the back plate. The injured employee's hand was crushed between the header and back plate, resulting in a partial amputation to his left index and middle fingers.

Amputation Finger(s), fingernail(s), unspecified Metal, woodworking, and special material machinery, unspecified

Pall Corporation

An employee was operating a machine when a wire pulled his right glove resulting in amputation of the index and middle fingertips.

Koch Foods of Cincinnati

An employee was grinding chicken when their right index fingertip was caught in the grinder and amputated.

Stella-Jones Corporation

An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.

Mack Manufacturing, Inc.

An employee was passing through a large metal door when the door closed on the employee, resulting in a cracked rib.

Nutmeg Container Corporation

An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.

Rae Corporation

An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.

American Event Services LLC

An employee was holding a piece of rubber while it was being cut on a band saw. The saw blade amputated his right middle fingertip without bone loss.

Coil Specialist, Inc.

An employee was observing expansion rods on a coil expander going into a coil to ensure copper stubs weren't being bent. His left hand was caught between the locking block and locking block clamp on the power press machine, resulting in partial amputation of his left little finger from the distal interphalangeal joint.

American Event Services LLC

An employee was setting up a press brake and rolling over a die when the tip of their left little finger was caught between the horizontal working surface of the press brake and die. The employee sustained partial amputation of their fingertip.

JC Residential and Light Commercial LLC

An employee was working to remove an access panel to begin performing maintenance on a machine. The set pins on the bottom of the panel were broken. The bottom kicked out and fell, striking the employee's left foot and resulting in a fracture to the big toe.

GS II Building Products, Inc.

An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Alfa Insurance

During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.

EMORY UNIVERSITY HOSPITAL

An employee slipped on condensation on a walkway in a parking garage. She fell and suffered a closed fracture to the neck of the left femur.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.