105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Freedom Solar LLC

Exposure to environmental heat · Effects of heat and light, n.e.c.

Federal OSHA recorded a severe workplace injury at Freedom Solar LLC, 1600 Hidden Bluff Court, PROSPER, TEXAS 75078 on — Effects of heat and light, n.e.c., affecting the bODY SYSTEMS.

An employee was working on a roof installing solar panels when they began to feel ill, resulting in hospitalization due to dehydration.

Hospitalized BODY SYSTEMS Heat-environmental

Freedom Solar LLC

An employee was adding low-voltage current transformers to a photovoltaic system. An arc flash burned the employee.

Freedom Solar LLC

An employee was coming down a portable ladder when they slipped and fell to the ground, resulting in a right forearm fracture.

View Freedom Solar LLC's full OSHA safety record →

Great Northwest Concrete

An employee was performing finishing work on a residential driveway when they began to experience body cramps and were hospitalized for heat stress and dehydration.

Lady Moon Farms, Inc.

An employee was staking tomato plants on a farm. The employee began to feel sick and collapsed, suffering from dehydration and heat shock.

Federal Bureau of Investigation

An agent was participating in SWAT team selection and was performing various physical fitness skills including running and exercise intervals. The agent experienced dehydration and a muscular injury that required hospitalization.

Hi-Tech Roofing & Sheetmetal, Inc.

An employee was traveling back from work when they became ill and experienced dizziness due to heat exhaustion.

2911 Logistics

On September 26, 2023, an employee was delivering packages when he began to feel ill with a pain in his side. He was hospitalized for heat exhaustion and dehydration.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

Mintcrest Corp

An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.

Cupertino Electric, Inc.

An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.

Swedberg Electric, LLC

The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC