Contact with hot objects or substances · Second degree heat (thermal) burns
At a glance
Federal OSHA recorded a severe workplace injury
at Evers Electric Inc., 5082 AR 4, ARKANSAS CITY, ARKANSAS 71630
on — Second degree heat (thermal) burns, affecting the upper and lower limb(s).
Watch Evers Electric Inc. — freeGet an email when a new federal OSHA severe-injury report for Evers Electric Inc. is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was working from inside a bucket and was guiding electrical wire when a steam line blew hot steam onto the employee from 10 feet above. The employee was hospitalized with first- and second-degree burns to both forearms and the right knee.
HospitalizedUpper and lower limb(s)Steam, vapors-nonchemical
An employee connected a steam line to a hose to clean equipment when the fitting broke loose. They were struck by steam in the left inner thigh, resulting in burns that required hospitalization.
An employee was making tea when she noticed tea grinds were collecting on the side and water was no longer dripping through the funnel. The employee was checking the funnel when boiling water and tea grinds spilled onto the left side of her body. The employee sustained burns to her neck, back, and arm.
An employee had turned off the ball valve on a waterpipe system and was removing the plug when the coupling system attached to the strainer came apart. Hot water sprayed on his arm and back, resulting in first- and second-degree burns that required surgery.
An employee was using a shovel to remove waste vermiculite from molten zinc. The metal had been placed in a bin and partially hardened. The employee broke through the partially hardened metal; still-molten metal flowed to the employee's steel-toed right boot and entered through the cloth boot tongue. The employee suffered a third-degree burn to the right foot and was hospitalized.
More severe injuries in this industry (NAICS 238210)
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.
An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.
On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.