Struck by discharged object or substance · Cuts, lacerations
At a glance
Federal OSHA recorded a severe workplace injury
at Gates Corporation, 1801 N. Lincoln St., SILOAM SPRINGS, ARKANSAS 72761
on — Cuts, lacerations, affecting the hand(s), except finger(s).
Final narrative
On 8/9/2023, an employee was pressure washing a mandrel shell when the pressurized mixture lacerated their right hand near the thumb. The employee was hospitalized.
Two maintenance technicians were changing out drive belts on the south end of the vulcanizing vessel. To check the proper function of the drive belts, the technicians manually cycled the cars into and then out of the vessel. One technician was manually cycling the vessel back out and the injured technician was inspecting the belts and checking the tension. The injured technician's right index finger was pinched between the belt and the pulley, resulting in an amputation of the distal phalanx.
An employee was cleaning a mandrel shaft with an emery cloth when their glove became caught on the rotating shaft. Their right hand was pulled in with the glove and their thumb was amputated.
On February 20, 2024, at approximately 6:30 a.m., an employee was unjamming rubber that had become stuck in a machine. When the machine started, the flapper moved, striking and compressing the employee. The employee was hospitalized for three fractured ribs, a partially collapsed lung, and a puncture wound in the middle of their back.
An employee was operating a hose/bender machine. He was reaching to adjust a piece of hose and got caught in a pinch point, sustaining an amputation to his finger.
An employee was installing wood trim surrounding a skylight inside a home. While holding a piece of trim in it's desired location, his pneumatic nail gun discharged, sending a 3/4-inch pin nail into his left forearm.
An employee removed a safety valve on a trailer that unknowingly contained nitrogen gas. The gas released from the trailer and pushed the employee backward off a scaffold approximately 10 feet before they struck a garage door, resulting in a pelvic injury.
An employee was sitting at her workstation when a nail gun malfunctioned and shot a nail into her left leg. She suffered a puncture and blood vessel injury and was hospitalized.
On November 25, 2023, an employee was using a high-pressured water hose to perform sewer line cleaning operations. The employee's right little finger and palm were lacerated by pressurized water from the hose.
An employee was preparing to cut rubber stock on a pneumatic cutting machine when their middle and ring fingertips were amputated by the cutting blade.
At about 12:25 a.m. on September 3, 2025, an employee was troubleshooting a malfunction involving a slitter whose arbor was not rotating as expected. The employee was observing the slitter's operations when the arbor completed its cycle and the employee's right index finger was drawn into the slitter's 4-inch, non-rotating cutting blade. The fingertip was amputated.
An employee was operating a rolling rope machine. Tooling fell out of the machine and landed on the employee's foot, breaking bones. The machine was not guarded at the time.
An employee was operating a machine when hot air and water was released. The employee sustained burns to the neck, back, buttocks and leg on the right side.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.
An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.
On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.