Injured by slipping or swinging object held by injured worker · Cuts, lacerations
At a glance
Federal OSHA recorded a severe workplace injury
at Nitram Excavation & General Contractors, INC., Cape Jellison Road, STOCKTON SPRINGS, MAINE 04981
on — Cuts, lacerations, affecting the upper arm(s).
Final narrative
An employee was using a saw to cut a water main inside of a trench when the saw kicked back. The employee sustained a biceps laceration that damaged the muscle and a vein.
An employee was using a saw to cut a piece of concrete when the piece gave way and pushed the saw into the employee's leg. The employee's leg was lacerated, requiring stitches and hospitalization.
An employee was grinding some hardfacing on a bulldozer blade when the 9-inch grinder kicked back and lacerated his left leg above the knee. The employee was hospitalized and required surgery.
An employee was operating a rotating tool to place thread protectors on the end of pipe. Her left hand was on the rotating part of the tool when the tool engaged, resulting in a left forearm fracture and a thumb laceration.
More severe injuries in this industry (NAICS 238910)
An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.
An employee was assisting the crew with patching and restoring a roadway after the installation of a sewer line. He was helping place and level the blacktop/backfill material over the trench area to bring the road surface back to proper grade. The employee was walking between a forward-moving dump truck and a dirt pile when his right foot was run over by the truck s wheel, causing him to fall. The employee sustained injury to his foot.
An employee was operating a skid steer with a bucket attachment at a demolition site. While driving it to the rear of the property to park it, the employee came into contact with a live electrical transformer unit that was located outside of the facility. The employee sustained electrical burns on his hands extending up to his elbows and a fractured ankle.
An employee was installing a door on a semi-trailer. They were using a forklift to lift the door to the height of the trailer when the door became jammed between the forklift mast and the hinge on the trailer. When the employee went to dislodge the door from the mast, the door fell and crushed their foot. Their big toe was amputated. The employee was hospitalized and their big toe was surgically reattached. The employee's foot and other toes also required surgery.
A crew was installing drilled micropiles alongside an outdoor covered deck foundation. The injured employee was working the front of the drill when a loose section of casing dropped onto the tip of a rig wrench and pulled the wrench down to an embedded casing. The employee's left little finger was caught between the rig wrench and the embedded casing and was amputated above the top knuckle.
Two employees were working to change a tire on a mobile slasher saw. The slasher weighs around 2,000 pounds and is towed. Employee 2 was lifting the saw while the injured employee was placing a block of wood under the frame for support. The slasher then lowered onto the block and the injured employee's left thumb was crushed between the slasher frame and the wood block, leading to an amputation at the first knuckle.
An employee was using a crane to move a 44-foot, 3,343-pound I-beam. As the beam was moving west, it straightened out (north to south), beginning to swing south toward the northwest corner of a building. The crane then sent the beam southward, directly toward the corner of the building. The beam caught the tips of the employee's left index, middle, and ring fingers against the building. The last joints of the middle and ring fingers were amputated, and the last joint of the index finger was partially crushed.
An employee was standing on a step stool, removing the nuts and bolts from the frame of a solar panel that was being replaced. The employee's cheek made contact with a connector with damaged insulation. The employee was shocked, briefly lost consciousness, and fell to the ground, suffering an injury to the left shoulder.