Federal OSHA recorded a severe workplace injury
at Sumter Utilities, Inc., Powerline Right- of- Way, HOPE HULL, ALABAMA 36043
on — Fractures , affecting the Leg(s) unspecified.
Final narrative
On January 9, 2024, an employee performing powerline restoration was climbing onto a truck when he fell to the ground. He was hospitalized with a fractured right leg.
A crew was performing a pole change-out when the injured employee contacted a live underground cable. The employee sustained an electrical shock and was hospitalized.
An employee was helping to move a power pole. The aerial crane carrying the pole made contact with 7,200-volt power lines, and the employee suffered first and second degree electrical burns to the right foot.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.
More severe injuries in this industry (NAICS 238210)
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.
An employee was traveling down the maintenance aisle of a warehouse on a single-pallet front rider jack. The jack malfunctioned, causing the brakes to apply; the employee fell forward onto the concrete warehouse floor. The employee suffered an injury to the left leg and was hospitalized, requiring surgery.
An employee was operating a metal roller machine to roll a small piece of metal. The employee's right index finger became caught between the metal and the machine, and the fingertip was amputated.
An employee was directing a truck driver to a dump site when the truck's peanut trailer slipped off the kingpin. As the trailer fell, a ladder attached to it lacerated the employee's ear. The employee was hospitalized.
An employee was unloading a forklift from a trailer to the ground. The employee was climbing down the ladder of the trailer when their foot slipped through one of the rungs, causing them to fall backward onto the forklift forks. The employee was hospitalized for fractured ribs.