105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

PPG Industries, Inc

Caught or wedged between objects nonrunning · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at PPG Industries, Inc, 2803 Spur 469, ENNIS, TEXAS 75119 on — Amputations, avulsions, enucleations unspecified, affecting the Other finger(s) n.e.c..

Watch PPG Industries, Inc — free Get an email when a new federal OSHA severe-injury report for PPG Industries, Inc is published. One employer, no account, unsubscribe in one click.

An employee was clearing a clog out of a line when the air line was pulled from the valve depleting the air in it, which caused the valve to close on their left thumb. They sustained a partial amputation of the top of the thumb.

Hospitalized Amputation Other finger(s) n.e.c. Valves, nozzles

PPG Industries, Inc.

An employee was loading a truck. The employee fell between the truck and the loading dock, sustaining an injury to the right ankle that required surgery and hospitalization.

PPG Industries, Inc.

An employee was throwing glass into the rework hopper when the glass slipped out of his hand and contacted his neck, lacerating it and requiring hospitalization.

PPG Industries, Inc.

An employee was cleaning sludge from the storm water/spill collection sump at the tanker unload area. He was attempting to return a section of heavy metal grate back into the operational position when he amputated his fingertip.

View PPG Industries, Inc's full OSHA safety record →

Great Dane Ltd. Partnership

An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.

Milk Specialties Global

An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.

GXO Logistics

On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.

Zimmerman & Herr

An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.

Certainteed Gypsum West Virginia, Inc

An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.

WL Plastics

Employees were hooking up a new reel of pipe to be processed into shorter lengths. This process involved routing a winch cable through a haul-off and attaching it to the pipe using a clamp. One employee held the winch cable while another pressed the feed-out button to loosen the cable. The cable tightened and pulled the hand of the employee holding it into a pulley. The employee's right index and middle fingertips were amputated at the first knuckle.

NOV Fiber Glass Systems

An employee was overseeing production on a winder machine and went to clear a jam when the head stock amputated their right thumb and index fingertip.

Advanced Drainage Systems, Inc

On 8/22/2025, an employee was working to clear a grinder jam. The employee was using a "no-touch tool" to rotate the drum of the grinder. He slipped forward and his right hand contacted a pinch point between the backside of the blade and the grinder housing. The employee's right middle fingertip was partially amputated with bone loss.

Georg Fischer LLC

At about 1:25 a.m. on August 14, 2025, an employee was operating a 10-inch band saw at a molding machine. The employee was working to cut the sprue off a PVC fitting. The blade snagged on the sprue and pulled his left index finger into the blade, which cut it. The finger was partially medically amputated.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.