Bright Star Solutions, Inc

Other fall to lower level unspecified · Fractures

Federal OSHA recorded a severe workplace injury at Bright Star Solutions, Inc, 1423 N Market St., SOUR LAKE, TEXAS 77659 on — Fractures , affecting the Leg(s) unspecified.

An employee was exiting a bucket truck after placing a hoist inside the bucket when they tripped and fell to the ground. The employee sustained a fractured leg.

Hospitalized Leg(s) unspecified Boom truck, cherry picker

Bright Star Solutions, Inc

An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.

Bright Star Solutions, Inc

On 6/11/2025, a lineman was removing a dead tree off of a powerline that had fallen due to thunderstorms. The employee cut the top of the tree to lessen the weight of the tree. He then hooked a jib line to the tree to lift it off the power line and place it on the ground. As he was moving his bucket into position, the tree shifted and fell, and the powerline released its tension. This caused a whipping effect and either the power line or the jib rope struck the employee's jaw. The employee was hospitalized with two fractures to his lower jaw.

View Bright Star Solutions, Inc's full OSHA safety record →

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

Garden Angels New York LLC

An employee was cleaning leaves with a backpack blower when he fell from a ladder, resulting in injuries to his head, neck, and back.

Foundation Steel, LLC

An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.

NYU Langone Hospital-Brooklyn

An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.

Cherokee Electric Cooperative

An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.

Centerpoint Energy Houston Electric, LLC

A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.

Public Service Electric & Gas

An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.

Bright Star Solutions, Inc

An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.