Struck by other falling object n.e.c. · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Lincoln Electric Automation - Coldwater, 911 North 2nd Street, COLDWATER, OHIO 45828
on — Amputations, avulsions, enucleations unspecified, affecting the Other finger(s) n.e.c..
Final narrative
On August 7, 2024, an employee was adjusting a spreader bar that was suspended in the air by a crane. When the employee removed a pin from the bar, it collapsed and pinched the employee's left index finger. The finger was partially amputated.
Amputation Other finger(s) n.e.c. Hoisting accessories n.e.c.
More severe injuries at Lincoln Electric Automation - Coldwater
On July 26, 2025, an employee was assembling a custom-designed automation line. During troubleshooting, he made contact with a photoelectric sensor that was part of the machine s part detection system. This triggered a small pneumatic crimping cylinder, which activated and came down on the tip of his right thumb, resulting in a partial amputation without bone loss.
The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
An employee was cleaning the floor by a belt conveyor when their right arm contacted the pulley/belting. His arm was pulled into the conveyor assembly, resulting in a fracture to his upper arm.
A backhoe tractor was moving gravel into a 1-foot-deep trench, and an employee was helping spread the gravel. The trench had been partly filled and the tractor was returning to it with a load of stone when its raised bucket struck the employee, who was standing in the trench. He was hospitalized, having suffered an abdominal injury that caused internal bleeding.
An employee was inside the frame of a traveling water screen that was up on sawhorses. The employee was working to fit a foot-shaft assembly onto the boot section when their left index finger was crushed and fractured between the sprocket and the set collar or chain. The fingertip was amputated.
On July 26, 2025, an employee was assembling a custom-designed automation line. During troubleshooting, he made contact with a photoelectric sensor that was part of the machine s part detection system. This triggered a small pneumatic crimping cylinder, which activated and came down on the tip of his right thumb, resulting in a partial amputation without bone loss.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.