Caught or wedged between objects nonrunning · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at PALFINGER North America, LLC., 341 Northwest 122nd Street, OKLAHOMA CITY, OKLAHOMA 73114
on — Amputations, avulsions, enucleations unspecified, affecting the Other finger(s) n.e.c..
Final narrative
An employee was using an overhead crane to set a complink into a rack. The front pin became stuck on the rack and would not go in. The employee let linkage off the crane and was manually moving the pin into place when his left index finger was pinched between the complink and the rack. The employee sustained an amputation to the top of the finger.
Amputation Other finger(s) n.e.c. Source, secondary source unspecified
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
More severe injuries in this industry (NAICS 336211)
An employee was walking on a dock plate to open the door for the next trailer. He tripped on a cargo strap that was laying on the dock and fell. The employee sustained a fractured right hip, requiring hospitalization and surgery.
On September 18, 2025, an employee was rolling a stack of two steel racks containing automobile bumpers when the top rack dropped, pinching their right little finger. The employee suffered a partial amputation.
An employee was exiting an ambulance when his foot slipped, causing him to hit either the portable aluminum step or the concrete floor. He suffered a broken left elbow.
Two employees were sliding a 200-pound steel mounting plate off a worktable onto the forks of a forklift. They slid the plate until it was half on the table and half on the forklift, and were making an adjustment to get the plate fully on the forklift when the plate pinched one employee's left ring finger. He suffered a partial amputation to the fingertip.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.
An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.
An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.