Exposure through intact tissue · Chemical burns, corrosions degree unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Archem America, Inc, 6350 Inducon Drive East, SANBORN, NEW YORK 14132
on — Chemical burns, corrosions degree unspecified, affecting the Multiple body parts n.e.c..
Final narrative
Two employees were servicing a chemical pour robot when they were sprayed with isocyanate. Both employees were hospitalized due to chemical contact with their eyes, face, and body.
Hospitalized Multiple body parts n.e.c. Chemicals and hazardous materials unspecified
An employee was removing a hose from a chemical tank after filling the tank with hexamethylenediamine (HMD). He checked the line to ensure that the hose was clear, then disconnected the hose at the connection. Residual chemical sprayed onto his face, causing a second-degree burn. He was hospitalized.
A shipping/receiving operator was working on a loading rack, loading a railcar. A 2-inch discharge cap failed and released pressure along with sulfuric acid from the railcar. The acid sprayed onto the employee, who suffered burns to the chest and the lower facial area. The employee was hospitalized.
An employee was pressure washing truck scales when they were splashed with water and an unknown chemical on their leg and immediately experienced a burning sensation. The employee was hospitalized with a chemical burn and required surgery.
An employee was on a ladder disconnecting a 1-inch hose, known to have last carried acrylic acid that had been drained. When the hose was disconnected, residual acid dripped onto the employee's shoulder/arm area, causing a second-degree chemical burn.
Employees were removing scaffolding that was used to repair an ion exchange tank. The line was undergoing the regen process when a piece of scaffold struck a PVC pipe that transported hydrochloric acid (HCl). The injured employee was placing material inside a scaffold rack when he was sprayed in the face with HCl and sustained chemical burns to his eyes, face, chest, right arm, and left leg.
More severe injuries in this industry (NAICS 326150)
On July 22, 2025, an employee was cutting/torching a large piece of metal when a piece of the material broke loose, struck him mid-stomach, and knocked him to the ground. The employee was hospitalized with an umbilical hernia and fractures to his right femur and left fibula.
An employee was feeding material through a pinch roller. There was a line break and the employee was working to clear out the line. The closed roll grabbed his glove and pulled his entire arm through the machine. The employee sustained compartment syndrome and a broken fingertip requiring hospitalization.
An employee hooked up two bundles of steel tubing to be lifted with an overhead crane. He stumbled while walking and operating the crane and his right hand contacted the crane's pulley mechanism. The upward motion of the crane caused the cable to pull his finger into the pulley. The employee's fingertip was partially amputated.
The employee was operating a peeler machine when his left hand got caught against the log that was being peeled. The employee was hospitalized with lacerations to the fingers on his left hand that required stitches.
An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.
An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.
An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.