Fall to lower level resulting from exposure or contact unspecified · Other multiple traumatic injuries n.e.c.
At a glance
Federal OSHA recorded a severe workplace injury
at Nantze, Inc., 1015 North Bishop Street, TEXARKANA, TEXAS 75501
on — Other multiple traumatic injuries n.e.c., affecting the Multiple upper extremities locations n.e.c..
Final narrative
An employee was on a ladder inside a ceiling grid to strip a live electrical wire. The wire stripper he was holding contacted the live wire, resulting in a shock that caused him to fall from the ladder. The employee suffered a dislocated and broken left shoulder as well as second- and third-degree burns on his left finger.
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was working as a fire watch. The employee was exposed to anhydrous ammonia and was not able to see while climbing down a ladder due to eye irritation. The employee fell and was hospitalized for a broken ankle.
An employee was working from a ladder and adjusting a spreader guide roller with a T-handle Allen wrench. The employee came into contact with an electrical junction box/wires, was shocked, and fell off the ladder to the concrete floor. He suffered a broken right-side rib, a puncture in the right lung, and an electrical shock burn to the right palm.
An employee was on a 10-foot ladder, working to insulate 24-inch piping that was 12 feet above the ground. The pipe jack/steel tube used to raise the pipe slipped, causing the steel tube to strike the employee's face. The impact caused the employee to fall off the ladder and sustain fractures to their left tibia and fibula.
An employee was on a rooftop, supervising the lifting of a 30' x 30' structure manufactured from I-beams. The employee was knocked to the ground and the suspended load settled on them. The employee sustained a head injury, loss of an eye, and fractured ribs.
More severe injuries in this industry (NAICS 238210)
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.