Struck by dislodged or detached object(s) · Cuts, lacerations, punctures without injury to internal structures
At a glance
Federal OSHA recorded a severe workplace injury
at Pella Corporation, 2000 Proline Place, GETTYSBURG, PENNSYLVANIA 17325
on — Cuts, lacerations, punctures without injury to internal structures, affecting the Chest unspecified.
Final narrative
An employee was performing a preventative maintenance check of a machine. While the machine was being cycled for a function check, a piece of its upper punch broke off and punctured the employee's chest.
Hospitalized Chest unspecified Vehicle and machine parts unspecified
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
A service crew was pulling a pump and motor from a well. After breaking a joint of pipe loose from another joint, an employee grabbed the chain tongs to prevent the pipe from spinning in the well, so the crew could continue taking it apart. The bolt that attaches the chain to the handle of the chain tongs broke, causing the chain to swing around and strike the employee's lower right leg. The chain severely punctured his leg and fractured his tibia.
An employee was using a handheld grinder to cut a bolt. The grinding wheel broke apart and a fragment struck the employee s right hand, causing a laceration to the palm near the little finger.
An employee was operating a brake press when the top die broke, causing the bottom die to roll out and onto the employee's legs. Both of the employee's legs were crushed below the knee, and both legs were partially amputated. The employee's left leg was also fractured above the knee.
A pressurized aircraft nose landing gear strut assembly was being disassembled. The gland nut dislodged under pressure and made contact with an employee's left hand, breaking it.
More severe injuries in this industry (NAICS 321911)
An employee had been unloading material from a drop table. When the employee reached to remove parts from a bin, the drop table came down on their right middle finger. The fingertip was amputated.
An employee was loading sliding doors and window panels onto a truck when the sliding doors fell on top of them. The employee sustained a pelvis fracture and internal injuries and was hospitalized.
The injured employee was working alongside a trainer. The trainer was adjusting the side fences that hold the wood in place as it passes through the molder. The injured employee was using compressed air to clean the area. They went to remove a sliver of wood to prevent a potential jam. The rollers activated, which processed material through the machine, caught the employee s glove, and pulled their hand toward the cutting head of the molder. The employee sustained lacerations to their right middle and ring fingers and an amputation to the distal phalanx of the middle finger.
On August 11, 2025, an employee was operating a clamping machine that used two pneumatic cylinders to clamp boards together for gluing. While he was positioning a board, the control was activated and the clamp on one side of the machine closed. A fingertip on his right hand was caught between the clamp and the board. He suffered an amputation to the fingertip (involving a torn fingernail and surrounding skin) as well as a fracture to the last joint of the finger.
On July 21, 2025, an employee was working from a 10-foot step ladder while installing a 3-by-5-foot glass window pane on the outside of a new home under construction. The window fell from the frame and the employee went to catch it when the ladder slipped. The employee fell 5 feet to the ground and landed on small pieces of concrete left over from the foundation pour. The employee was hospitalized with a dislocated elbow and fractured wrist that required surgery.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.
An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.