Struck by dislodged or detached object(s) · Fractures and surface, flesh wounds
At a glance
Federal OSHA recorded a severe workplace injury
at High Roller Resources, LLC, : 32.11137771606445,-93.60121154, MANSFIELD, LOUISIANA 71052
on — Fractures and surface, flesh wounds , affecting the Nose and mouth.
Watch High Roller Resources, LLC — freeGet an email when a new federal OSHA severe-injury report for High Roller Resources, LLC is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was removing a bonnet from an oil and gas pipe. Residual pressure inside the pipe caused the bonnet to fly off and contact the employee. The employee was hospitalized with a chipped tooth and a fractured nose.
Hospitalized Nose and mouth Parts and materials unspecified
More severe injuries at High Roller Resources, LLC
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
A service crew was pulling a pump and motor from a well. After breaking a joint of pipe loose from another joint, an employee grabbed the chain tongs to prevent the pipe from spinning in the well, so the crew could continue taking it apart. The bolt that attaches the chain to the handle of the chain tongs broke, causing the chain to swing around and strike the employee's lower right leg. The chain severely punctured his leg and fractured his tibia.
An employee was using a handheld grinder to cut a bolt. The grinding wheel broke apart and a fragment struck the employee s right hand, causing a laceration to the palm near the little finger.
An employee was operating a brake press when the top die broke, causing the bottom die to roll out and onto the employee's legs. Both of the employee's legs were crushed below the knee, and both legs were partially amputated. The employee's left leg was also fractured above the knee.
A pressurized aircraft nose landing gear strut assembly was being disassembled. The gland nut dislodged under pressure and made contact with an employee's left hand, breaking it.
More severe injuries in this industry (NAICS 541330)
An employee was working to free a load by grabbing and shaking the live side of a tugger line. Once the load became free and progressed upward, the employee's hand was caught and pulled into a snatch block. The employee's right thumb was broken and lacerated. The employee was hospitalized and required a surgical amputation.
An employee was operating a drill rig when when their hand got caught between a 1/4-inch steel cable and a drill rod, resulting in the amputation of four fingers.
An employee was overseeing the operation of a rope being respooled onto the drum of a wire winding machine. He went to remove a piece of wooden reel from the rope. His glove got snagged and his right hand was pulled into the roller, pinching his fingers between the machine's roller and the rope. The middle and index fingers were crushed.
An employee was visiting a patient's home to fit them with a wearable cardiac defibrillator. As he was walking from the front door to his car, a large dog broke free from a chain and attacked him. He was bitten on the forearm and fell. The patient was then able to restrain the dog. The employee was hospitalized with severe dog bites and required surgery.
An employee tripped over a junior I-beam about 4 feet long and 6 inches tall that was installed for circulating water valves and fell to the ground, resulting in a broken right-side rib.
A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.
A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.
A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.
An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.